5) INTENDED AND IMPROPER USES OF THE STAIRLIFT
5.1) Intended use
The Mod. V64/74 stairlift is a system for transporting persons SEATED ON A WHEELCHAIR OR ON A
SPECIAL SEAT (optional) with STRAIGHT rail at CONSTANT gradient which can be installed on stairs
having the following characteristics:
- Ambient:
- Steps:
- Gradient:
User characteristics: Self-sufficient, physically and mentally suitable, familiar with the equipment's
operation and the use and maintenance instructions.
CAUTION: If the person using the system is not self-sufficient, the stairlift must be operated by
another person acting as attendant. While the lift is in motion, sit still and do not move or rock.
5.2) Improper uses
- Transporting objects on the platform
- Overloading the stairlift (e.g., disabled person with electric wheelchair having total weight in excess
of the maximum permitted load. See section 4, Technical Specifications).
- Use of the stairlift by unauthorised persons (e.g. children, people who do not meet the requirements
specified in point 5.)
Improper uses
Use on stairs having gradient greater than 50°
User standing on platform
Operation by unsuitable operator
Transporting more than one person
CAUTION: DO NOT MAKE MODIFICATIONS INTENDED FOR ANY USE, DO NOT INSERT EX-
TRANEOUS OBJECTS OR LIQUIDS IN HOLES OR CRACKS, DO NOT SPRAY LIQUIDS ONTO THE
STAIRLIFT
6) PREPARATION FOR COMMISSIONING
6.1) Preliminary checks
Checks to be made before the lift is put into service.
Skill level: OS - Specialist operator appointed by the manufacturer.
ITEM CHECKED
Controls:
Safety devices:
- Sensor edges
- Electric limit switches
- Over-limit switches
- Anti-crushing platform base
Power supply:
Earth connection:
Indoor and outdoor
Parallel
Minimum 0° - Maximum 50°
Problems
Risk of falling
RESULT OF CHECK
Correct operation in response to controls.
Correct timing of the start-up controls.
Efficiency of emergency stop.
Check that the safety device is tripped, stopping the lift.
Mains voltage and frequency as specified in point 6.2.
Check that the lift system's earth line is connected to the
earth line of the mains system.
8
Overheating of motor
Risk of falling
Risk of falling and of overheating of motor
7502116
Need help?
Do you have a question about the V64-74 B.I. and is the answer not in the manual?