Setting the heating curve:
- Activate the base point with the right softkey, set
with the rotary knob and conform with the right
softkey.
Base point
Fig. 49: Setting the base point
- The standard inlet temperature and the outside
temperature are set using the same procedure.
Standard ow temp.
Fig. 50: Setting the standard inlet temperature
Standard outside temp.
Fig. 51: Setting the outside temperature
Fixed-value-control heating cycle mode
Specify the set temperature for fixed value control
(select with the rotary knob and confirm with "OK").
The cycle is kept permanently at this temperature
in fixed value control.
For optimal configuration of the heating curve
parameters, the heating load calculation and/or
energy consumption must be taken into account.
Differences between the installed parameters and
the design of the actual building can cause the
heat pump to run inefficiently.
Operating the cycles with a fixed value is not rec-
ommended, as it will cause the heat pump to
operate inefficiently.
1st mixed cycle
Activate if a cycle with a panel heater is present
(select with the rotary knob and confirm with "OK").
Activate mixed circuit, if there is a mixing
valve.
1st mixed circuit
Fig. 52: Activate 1st mixed cycle
Menu item
Parameter
Deactivated
1st mixed
cycle
Activated
Press "Next".
Setting heating cycle mode
This is where you can select between the different
heating cycle modes. The choice is between reg-
ulation according to the set "Heating curve" and
"Fixed value control" (select with the rotary knob
and confirm with "OK").
Menu item
Parameter
Heating
Heating curve
cycle mode
for HK active
Fixed value
deactivated
Factory setting
Deactivated
Factory setting
According to
design
10 °C - 40 °C
35