REMKO Smart WP MANAGER
Load user settings
When first installing the controller this parameter is
confirmed with "NO".
If a new software status is installed after the initial
installation, it is possible to confirm this with "YES"
and all existing parameters will be accepted anew.
This means a complete new installation is unnec-
essary.
Please choose „yes" if you have done an
software update and you want to restore the
previous user settings.
Restore user settings?
Fig. 36: Load user settings
Activating the heat pump
The controller detects automatically that a heat
pump has been connected. If necessary, activate
the heat pump (select with the rotary knob and
confirm with "OK").
Activating the heat pump
Heat pump
Fig. 37: Activating the heat pump
Menu item
Parameter
Activating
Activated
the heat
Deactivated
pump
Press "Next".
30
no
activated
Factory setting
Activated
Set the number of heat pumps in your
installation.
1
Number of heat pumps
Fig. 38: Number of heat pumps
Menu item
Parameter
Number of
1 - 10
heat pumps
Activate the additional heat generator if a
second heat generator is installed.
Additional heat generator
Fig. 39: Auxiliary heat generator
Menu item
Parameter
Auxiliary
Activated
heat gener-
Deactivated
ator
Selection of the auxiliary heat generator:
- Activated (heat pump or oil/gas-fired boiler or wall
heating)
- Heat pump and/or Smart Serv electric heating
element according to usable limits
The operating mode of the internal pump in the
indoor unit must be defined here.
1
10
Factory setting
1
deactivated
Factory setting
Deactivated