Electrical connections

Transmitter, cable M12-C02PT2T
1
Pin
Wire
Function
1
Brown
Supply
2
White
TEST
3
Blue
Supply
4
Black
EARTH
5
Grey
Not used
1
Colours according to ABB Jokab Safety standard cable.
Receiver, cable for muting, M12-C02PT62RM
Receiver cable for muting, M12-12 connector
1
Pin
Wire
Function
1
Brown
Supply
2
Blue
Supply
RESET/
3
White
ACKNOWLEDGE/
ALIGN
4
Green
OVERRIDE1
5
Pink
OSSD2
6
Yellow
EDM
MUTING
7
Black
SELECTION
8
Grey
OSSD1
9
Red
OVERRIDE2
10
Violet
MUTING LAMP
OVERRIDE
11
Grey-pink
STATUS
12
Red-blue
EARTH
1
Colours according to ABB Jokab Safety standard cable.
2TLC172296M0201 Rev A
2015-03-20
Connection to
+24 VDC
NO contact to +24 VDC
0 V
Earth
-
Auto. Reset with no function
Auto. Reset with Acknowledge
function or Alignment mode
Manual Reset
Function used/activated
Function not used/deactivated
Possibility to disable the Muting
function during operation
No possibility to disable the Muting
function during operation
3
Connection to
+24 VDC
0 V
Not connected
NO contact to +24 VDC
NO contact to +24 VDC
NO contact to +24 VDC
Safety control module for example
NC contact of a force guided relay
Not connected
NO contact to +24 VDC
Not connected
Safety control module for example
NO contact to 0 V
Lamp between output and +24 VDC
- ON when Muting activated.
- Flashing during override.
Lamp, PLC input, HMI, etc.
- High when Override active.
- Low when Override inactive.
NB: this output can fluctuate at start-
up independently of the Override
function.
Earth