Honeywell Impact Series Operating Instructions And Maintenance Manual page 56

Table of Contents

Advertisement

Using your Cl
Cartridge
2
Please ensure that the following points are noted when the cartridge is in service.
1.
Always use PTFE tubing (maximum length of 500mm) and a flow rate of
500ml/min when calibrating the Cl
2.
Apply all gases to the port marked OUTLET (not INLET) on the Flow
Housing.
3.
With regard to the actual sensors fitted, please perform span calibrations
on the sensors of the Impact Pro cartridge in the following order: Cl
H
S, CO, Flammable.
2
4.
When performing a Span Calibration on the Cl
flow Cl
calibration span gas through connected tubing for a minimum of 15
2
minutes without the flow adapter fitted to the Impact Pro before attempting
a span calibration. Failure to do so may result in a false calibration of the
Cl
channel.
2
5.
Do not apply Span Calibration gas to the Impact Pro for greater than 5
minutes. Again failure to do so may result in a false calibration of the Cl
channel.
6.
This cartridge is not suitable for pumped mode operation.
7.
Due to the open nature of the Stainless Steel filter, there is a greater risk
of water damage occurring to the instrument. Every attempt should be
made to keep the instrument dry.
8.
Refer to the CAUTION given in
recommended daily checks on your gas detector.
Applied Gas
CO (100 ppm)
H
S (40 ppm)
2
CO
(0.5% v/v)
2
Cl
(5 ppm)
2
NH
(50 ppm)
3
Hydrogen
(1000 ppm)
SO
(10 ppm)
2
1
Reading displayed as -0ppm.
** Electrochemical CO
56
Effect
Effect
on CO
on H
S
2
Sensor
Sensor
100 ppm
0 ppm
0 ppm
40 ppm
0 ppm
0 ppm
0 ppm
0 ppm
0 ppm
0 ppm
200 ppm
0 ppm
0 ppm
0 ppm
cell only
2
Impact / Impact Pro / Impact Pro IR Operating Instructions
channel.
2
channel,it is good practice to
2
Section 1.1 of this manual for details on
Effect
Effect
on CO
on Cl
2
2
Sensor**
Sensor
0% v/v
0 ppm
0% v/v
-25 ppm
0.5% v/v
0 ppm
0% v/v
5 ppm
0% v/v
-2 ppm
0% v/v
TBA
0% v/v
2 ppm
Effect
Effect
on NH
on SO
3
Sensor
Sensor
35 ppm
1 ppm
50 ppm
1 ppm
1
0 ppm
0 ppm
-2 ppm
50 ppm
1
35 ppm
0 ppm
10 ppm
, NH
,
2
3
2
2
TBA
1
TBA