Electrical Connections (Series Tpfada / Tpha) - gefran MD Series Manual Of Electrical Installation

Pressure probes
Table of Contents

Advertisement

P - 7-pole connector
Male connector 09-127-09-07
Protection IP67
Z - 4-pole male connector
M12 x 1
2 1
3 4
4-pole series 713 male connector
Protection IP67
Series TPFADA / TPHA
Output amplified in current (mod. E)
CONTROLLER
AMPL/CONV.
CALIBRATION
Output amplified in voltage (mod. B/C/M/N/P/Q/R)
CONTROLLER
AMPLIFIER
P - 7-pole connector
Male connector 09-127-09-07
V - 6-pole connector
Male connector VPT02A10-6PT2
4
V - 6-pole connector
Male connector VPT02A10-6PT2
Protection IP66
E - 4-pole solenoid connector
M - 4-pole microsolenoid connector
Solenoid DIN 43650A - ISO4400
Protection IP65
Microsolenoid DIN 43650C - ISO4400
Protection IP65
Code
V
POWER SUPPLY
(10...30Vdc)
SIGNAL
(4...20mA)
NOT CONNECTED
C - D
The cable sheathing is connected to the transducer body
Code
V
POWER SUPPLY
(15...30Vdc)
OUTPUT
CALIBRATION
The cable sheathing is connected to the transducer body
E - 4-pole connector solenoid
M - 4-pole connector microsolenoid
E - Solenoid 400 DIN
46350A-ISO 4400
M - Microsolenoid 400 DIN
46350B-ISO 4400
Code
Code
Code
F
P
E/M
Red
Black
Blue/Orange
Not
available
1 - 2 - 7
3
Code
Code
Code
P
F
E/M
White
Green
Red
Black
Not
Blue/Orange
available
F - 4-pole cable
Orange
Shielding
Blue
Red
Black
F - Shielded cable 4 x 0,25 - 1m
(for output code E)
MAN_Electrical_Installation_for_Pressure_Probes_0709_ENG
F - 2-pole cable
Shield
Red
Yellow or
Black
Shielded cable 2x0,25 - 2m. (output E)
Protection IP65
F - 4-pole cable
White
Shield
Green
Red
Yellow or
Black
Shielded cable 4x0,25 - 2m
Protection IP65
LOAD DIAGRAM
(Current output)
POWER SUPPLY
F - 6-pole cable
Shielding
Red
Black
White
Green
Blue
Orange
F - Shielded cable 6 x 0,25 - 1m.
AREA OF
POSSIBLE
USE

Advertisement

Table of Contents
loading

Table of Contents