Models
Models
E-20 SERIES
Part,
Full Load
Series
Peak Amps*
259025, G
48
259030, G
24
259034, G
32
E-30 SERIES
Part,
Full Load
Series
Peak Amps*
259026, F
78
259031, F
34
259035, F
50
259057, F
100
259058, F
62
259059, F
35
E-XP1 SERIES
Part,
Full Load
Series
Peak Amps*
259024, G
69
259029, G
24
259033, G
43
E-XP2 SERIES
Part,
Full Load
Series
Peak Amps*
259028, F
100
259032, F
35
259036, F
62
* Full load amps with all devices operating at maximum
capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
Total system watts, based on maximum hose length
†
for each unit:
•
E-20 and E-XP1 series, 210 ft (64 m) maximum
heated hose length, including whip hose.
•
E-30 and E-XP2 series, 310 ft (94.5 m) maximum
heated hose length, including whip hose.
Maximum flow rate given for 60 Hz operation. For 50
Hz operation, maximum flow rate is 5/6 of 60 Hz
maximum flow.
4
Nominal Voltage
System
Range (phase)
Watts†
200-240 V (1)
10,200
350-415 V (3)
10,200
200-240 V (3)
10,200
Nominal
System
Voltage Range
Watts†
(phase)
200-240 V (1)
17,900
350-415 V (3)
17,900
200-240 V (3)
17,900
200-240 V (1)
23,000
200-240 V (3)
23,000
350-415 V (3)
23,000
Nominal
System
Voltage Range
Watts†
(phase)
200-240 V (1)
15,800
350-415 V (3)
15,800
200-240 V (3)
15,800
Nominal
System
Voltage Range
Watts†
(phase)
200-240 V (1)
23,000
350-415 V (3)
23,000
200-240 V (3)
23,000
Max Flow
Primary
Rate
Heater
lb/min
Watts
(kg/min)
6,000
20 (9)
6,000
20 (9)
6,000
20 (9)
Max Flow
Primary
Rate
Heater
lb/min
Watts
(kg/min)
10,200
30 (13.5)
10,200
30 (13.5)
10,200
30 (13.5)
15,300
30 (13.5)
15,300
30 (13.5)
15,300
30 (13.5)
Primary
Max Flow
Heater
Rate
Watts
gpm (lpm)
10,200
1.0 (3.8)
10,200
1.0 (3.8)
10,200
1.0 (3.8)
Primary
Max Flow
Heater
Rate
Watts
gpm (lpm)
15,300
2.0 (7.6)
15,300
2.0 (7.6)
15,300
2.0 (7.6)
Approvals
9902741
Conforms to ANSI/UL
Std. 499 Certified to
CAN/CSA Std.
C22.2 No. 88
Approximate
Maximum Fluid
Output per
Working Pressure
Cycle (A+B)
psi (MPa, bar)
gal. (liter)
0.0104 (0.0395)
2000 (14, 140)
0.0104 (0.0395)
2000 (14, 140)
0.0104 (0.0395)
2000 (14, 140)
Approximate
Maximum Fluid
Output per
Working Pressure
Cycle (A+B)
psi (MPa, bar)
gal. (liter)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
Approximate
Maximum Fluid
Output per
Working Pressure
Cycle (A+B)
psi (MPa, bar)
gal. (liter)
0.0104 (0.0395)
2500 (17.2, 172)
0.0104 (0.0395)
2500 (17.2, 172)
0.0104 (0.0395)
2500 (17.2, 172)
Approximate
Maximum Fluid
Output per
Working Pressure
Cycle (A+B)
psi (MPa, bar)
gal. (liter)
0.0203 (0.0771)
3500 (24.1, 241)
0.0203 (0.0771)
3500 (24.1, 241)
0.0203 (0.0771)
3500 (24.1, 241)
312065V