Operation
10. Manual current control mode only:
When in manual current control mode, monitor hose
temperature with thermometer. Install per instructions
below. Thermometer reading must not exceed 160°F
(71°C). Never leave machine unattended when in
manual current control mode.
a. If FTS is disconnected or display shows
diagnostic code E04, turn main power switch
OFF
then ON
diagnostic code and enter manual current
control mode.
to hose. Current is not limited by target
temperature.
b. Press
or
c. To prevent overheating, install hose
thermometer close to gun end, within operator
view. Insert thermometer through foam cover of
A component hose so stem is next to inner tube.
Thermometer reading will be about 20°F less
than actual fluid temperature.
d. If thermometer reading exceeds 160°F (71°C),
reduce current with
28
to clear
display will show current
to adjust current setting.
key.

Set pressure

Motor Controls and Indicators, see page 17
1. Press
.
2. Press motor
. Motor and pumps start. Display
shows system pressure. Motor runs until setpoint is
reached.
3. Press
or
fluid pressure. Display will show setpoint for 10
seconds, then change to actual pressure.
NOTE: If display pressure is greater than setpoint
pressure, trigger gun to reduce pressure.
NOTE: If display shows J xx, unit is in jog mode. To exit
jog mode, see page 33.
4. To display cycle count, press
NOTE: To clear counter, press
seconds.
5. Press
or
PSI
BAR
ON / OFF
PARK
PSI
BAR
until display shows desired
.
and hold for 3
to change pressure scale.