Mounting The Pump - Graco TRITON 3D350HP Instructions-Parts List Manual

Diaphragm pump
Table of Contents

Advertisement

Installation

Mounting the Pump

For ease of operation and service, mount the pump so
the air inlet, fluid inlet, and fluid outlet ports are easily
accessible. The inlet port must point down and the outlet
port must point up.
Use 5/8 in. lag screws or bolts for mounting.
To ensure proper operation, mount the pump in a
horizontal position.
Wall Mount Installation
1. Wall Mount Kit 245875 is available. See F
2. Be sure the wall can support the weight of the
pump, bracket, hoses and accessories, as well as
the stress caused during operation.
3. Using the wall bracket (B) as a template, drill 5/8 in.
mounting holes in the wall. See page 27 for a wall
mounting diagram. Mount the bracket 1.2-1.5 m (4-5
ft) above the floor.
4. Attach the bracket (B) to the pump (A) with the
screws (C) and washers (D) provided in the kit.
5. Attach the bracket to the wall. Use screws (E) that
are long enough to keep the pump from vibrating
during operation. Be sure the pump is level.
A
F
. 1: Wall Mount Kit
IG
6
Floor Stand Installation
Floor Stand Kit 245874 is available. See F
assemble.
. 1.
IG
F
IG
C
D
B
E
TI2079B
. 2: Floor Stand Installation
. 2 to
IG
TI20798

Advertisement

Table of Contents
loading