Geokon 4500-9-HDF1 Instruction Manual page 14

Armored cable splice kit
Table of Contents

Advertisement

8 | SPLICING PREP | GEOKON
7.
Remove the paper and 25 mm (1 inch) of inner jacket to expose the braided
shield.
Braided Shield
8.
Remove the braided shield to expose the two twisted pair wires and shield wire.
Shield Wire
9.
Remove the mylar wrapping to expose the 2 pair wire leads and shield wire.
10. Strip the insulation back approximately 12 mm (½ inch) on the red & black
gauge wires and on the green & white thermistor wires.
Gauge
Gauge
Shield
Thermistor
Thermistor
Note: Do not connect the fitting nut to the connector adapter until you after you
have finished splicing the wire leads. Refer to Section 2 for more information.
Inner Jacket
Twisted Pair Wires
Twisted Pair Wires
Armor
Armor