Fixed End Preparation - Geokon 4500-9-HDF1 Instruction Manual

Armored cable splice kit
Table of Contents

Advertisement

6 | SPLICING PREP | GEOKON
5.
Remove the mylar wrapping to expose the wire leads.
6.
Strip the insulation back approximately 12 mm (½ inch) on the red & black
gauge wires and on the green & white thermistor wires.
Note: Do not connect the fitting nut to the connector adapter until you after you
have finished splicing the wire leads. Refer to Section 2 for more information.
For instructions on making the splice, see Section 2.

1.2 FIXED END PREPARATION

1.
Unscrew and remove the cable fitting nut from the fixed end of the tube.
Connector Adapter
2.
Slide the black 02-500PEI armored cable through outer end of the Kellems
grip and and through the fitting nut.
Armored Cable
Note: Compress the Kellems grip lengthwise to aid in sliding the cable.
Grommet
Fitting Nut
Fitting Nut
Gauge
Gauge
Shield
Thermistor
Thermistor
Kellems grip
Kellems grip

Advertisement

Table of Contents
loading

This manual is also suitable for:

4500-9-hdf2