4 | SPLICING PREP | GEOKON
6.
Remove the braided shield to expose the two twisted pair wires and shield wire.
7.
Remove the mylar wrapping to expose the 2 pair wire leads and shield wire.
8.
Strip the insulation back approximately 12 mm (½ inch) on the red & black
gauge wires and on the green & white thermistor wires.
Note: Do not connect the fitting nut to the connector adapter until you after you
have finished splicing the wire leads. Refer to Section 2 for more information.
For instructions on making the splice, see Section 2.
Twisted Pair Wires
Twisted Pair Wires
Armor
Shield Wire
Gauge
Gauge
Shield
Thermistor
Thermistor