Error Code
System
Display System
ELV Lost
Elevation System
LCB Comm
Display System
Console is
having difficulty
Lower Board
communicating with
lower board
Drive system
Treadle ERR
(Treadclimbers only)
Lower board failure
Batt Low
Power system
Drive System
Maximum steps
SPM Overflow
per minute exceed
maximum range for
a specific level.
Possible Failure Points
• The display cable is damaged.
• The elevation motor is not plugged in to the MCB.
• The elevation sensor (potentiometer) is damaged.
• Console firmware needs to be updated to the latest version.
• Correct unit model needs to be selected in the service menu.
• Lower board needs the latest firmware update via FISP.
• Lower board to console wire harness is damaged or not fully connected.
• Lower board failure.
• Console failure.
• Related docs:
637-4297
• Treadle optical sensors
• Treadle optical sensor wire harness
• Lower board.
• This error can be triggered as a user walks and the range of motion is
limited which prevents one of the optical sensors from triggering. This is a
soft error that will not interrupt user operation – see 637-1534.
• Battery is dead and needs to be charged.
• Machine is not being used enough to keep battery charged.
• Battery is not being sufficiently charged by drive system.
• Battery wire harness is damaged or not fully connected.
• Alternator
• Alternator brushes
• Speed sensor
Page 43