Mitsubishi Electric MELSEC iQ-R RJ71LP21-25 User Manual page 41

Melsecnet/h network module
Hide thumbs Also See for MELSEC iQ-R RJ71LP21-25:
Table of Contents

Advertisement

• Normal station (station No.2)
Classification
Label name
Module label
LP21_1.bDetect_DataLinkError
LP21_1.bnSts_CyclicTransmissionError_Station[1]
Label to be defined
Define global labels as shown below:
(41)When 'bHandShake1' (B0) is turned on in the control station (station No.1), the contents of 'uData' (W0 to W3) is stored in 'uOutputData' (D100 to D103).
When data storage is completed, 'bHandShake2' (B100) is turned on.
(48)When 'bHandShake1' (B0) in the control station (station No.1) is turned off, 'bHandShake2' (B100) is turned off.
Description
Data link error status of own station
Data link status of each station
(station No.1)
7 COMMUNICATION EXAMPLES
7.1 Cyclic Transmission Program
Device
SB0049
SW0074.0
7
39