Table 3 Table; Electrical Specifications - Bard I-TEC Series Installation Instructions Manual

Packaged heat pump
Table of Contents

Advertisement

Rated
No.
Volts,
MODEL
Field
Hertz &
Power
Phase
Circuits
I36Z1-A0Z
1
A05
1
230/208-1
A10
1 or 2
A15
1 or 2
I36Z1-B0Z
1
B06
1
230/208-3
B09
1
 B15
1
I36Z1-C0Z
1
C06
1
460-3
C09
1
 C15
1
I48Z1-A0Z
1
A04
1
A05
1 or 2
230/208-1
A10
1 or 2
 A15
1 or 2
 A20
1 or 2
I48Z1-B0Z
1
B06
1
B09
230/208-3
1
 B15
1
 B18
1
I48Z1-C0Z
1
C06
1
C09
230/208-1
1
 C15
1
 C18
1
I60Z1-A0Z
1
A05
1 or 2
A10
230/208-1
1 or 2
 A15
1 or 2
 A20
1 or 2
I60Z1-B0Z
1
B06
1
B09
230/208-3
1
 B15
1
 B18
2
I60Z1-C0Z
1
C06
1
C09
460-3
1
 C15
1
 C18
1
These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 310
for power conductor sizing.
Caution: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of table
310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.
Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
Maximum KW that can operate with the heat pump is 10KW for 1-Phase and 9KW for 3-Phase.
Represents Electric Heat only. Electric Control Circuit will lock-out Heat Pump Operation.
Manual 2100-578L
Page
6 of 42
TABLE 2

Electrical Specifications

Single Circuit
Maximum
Minimum
Field
External
Circuit
Power
Fuse or
Ampacity
Wire Size
Ckt. Brkr.
26
40
8
52
60
6
78
80
4
84
90
4
22
30
10
40
45
8
49
50
8
51
60
6
11
15
14
20
20
12
24
25
10
28
30
10
34
50
8
54
60
6
59
70
6
85
90
3
85
90
3
110
110
2
26
35
8
44
50
8
53
60
6
53
60
6
53
60
6
15
20
12
25
30
10
29
30
10
29
30
10
29
30
10
44
60
8
70
80
4
96
100
3
96
100
3
112
120
2
31
45
8
49
60
8
58
60
6
58
60
6
15
20
12
25
30
10
29
30
10
29
30
10
29
30
10
Minimum
Maximum
Circuit
External Fuse
Ground
Ampacity
or Ckt. Breaker
Wire
Ckt.
Ckt.
Ckt. A
A
B
10
10
8
26
52
40
8
26
52
40
10
10
10
10
14
12
10
10
10
10
8
35
26
45
8
35
52
45
8
35
52
45
6
59
52
60
10
10
10
10
10
12
10
10
10
10
10
8
44
26
60
8
44
52
60
8
44
52
60
6
60
52
60
10
10
10
10
31
54
45
12
10
10
10
10
Multiple Circuit
Field Power
Ground Wire
Wire Size
Size
Ckt.
Ckt.
Ckt.
Ckt.
B
A
B
A
60
8
6
10
60
8
6
10
30
8
10
10
60
8
6
10
60
8
6
10
60
6
6
10
30
8
10
10
60
8
6
10
60
8
6
10
60
6
6
10
60
8
6
10
Ckt.
B
10
10
10
10
10
10
10
10
10
10
10