Description Of The Camera Control Commands (Bank Number: 00H) - Omron STC-APB503PCL Product Specifications And User's Manual

Monochrome / color cmos camera
Table of Contents

Advertisement

9.4.2

Description of the camera control commands (Bank number: 00H)

The underline settings are the factory default settings.
Command No.
Command Description
10H:
[Camera function mode 1] Default data: MOD1 [7..0] = 01H
MOD1 [7..0]
Sets the camera function mode.
D7
D7
D6
D5
D4
D3 to D1
D0
*1 Only available for monochrome model (Please sets 0 for color model)
11H:
[Camera function mode 2] Default data: MOD2 [7..0] = 00H
MOD2 [7..0]
Sets the camera function mode.
D7
D7 to D4
D3
D2 to D0
* Note: While the camera is in trigger mode, the image will not output without the trigger signal input.
12H:
[Camera function mode 3] Default data: MOD3 [7..0] = 40H
MOD3 [7..0]
Sets the camera function mode.
D7
D7 to D6
D5
D4 to D0
14H:
[Communication mode] Default data: UART [7..0] = 01H
UART [7..0]
Sets the communication mode.
D7
D7 to D2
D1 to D0
STC-APB503PCL / STC-APC503PCL
Product Specifications and Use's Guide
D6
D5
D4
D3
Trigger Mode Selection
Trigger Polarity
Trigger Mode
Binning Mode *1
No Function
CMOS Shutter Mode
D6
D5
D4
D3
No Function
Operation Mode
No Function
D6
D5
D4
D3
Output Format
Trigger Input
No Function
D6
D5
D4
D3
No Function
Communication Mode
D2
D1
D0
0: Auto
0: Positive
0: Edge Preset
0: OFF
Always set as "000"
0: Rolling (ERS)
D2
D1
D0
Always set as "0000"
0: Trigger
Always set as "000"
D2
D1
D0
00: 10bits
10 to 11: No Function
0: CC1 on Camera Link
Always set as "00000"
D2
D1
D0
Sets always as "000000"
00: 38,400 bps
10: 57,600 bps
No.19S019-01
1: Manual
1: Negative
1: Pulse Width
1: ON
1: Global Reset (GRR)
1: Free-run / Continuous
01: 8bits
1: 2pin on power-I/O
01: 9,600 bps
11: 115,200 bps
1
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stc-apc503pcl

Table of Contents