New fraction configurations are made available in the new firmware. The following step must be performed for fraction
configured flowmeters:
Go to menu item 2.2.7.3 "Active Fraction" and press
and press
.
Note: If the ordered fraction is not found on the list, then select the last option "Empty".
Reinstate display and display lid
Reconnect display cable and carefully push display back into housing.
Remove the O-ring from the lid.
Reinstate the display lid until mechanical stop. Wind back the lid by one turn.
Mount the O-ring by pulling it over the display lid; then turn the lid until you feel friction from the O-ring on both sides.
Wind the display lid by one quarter of a turn to seal on the O-ring and tighten the fixing screw.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
FC430 upgrade instructions - Compact
A5E33310535, 06/2016
8
. From the list, select the fraction used in the application,
FC430 upgrade instructions - Compact
A5E33310535-AG, 06/2016