Astria Fireplaces Aries C Series Installation And Operation Instructions Manual

Millivolt direct-vent gas fireplaces
Hide thumbs Also See for Aries C Series:

Advertisement

P/N 900921-00 REV. E 06/2019
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900921-02
P900921-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Aries™ -C Series Millivolt Direct-Vent Gas Fireplaces
Models
ARIES35RMN-C
C
US
ARIES35RMP-C
Report No. F13-094
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
ARIES35TMN-C
ARIES35TMP-C
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
ARIES40RMN-C
ARIES40TMN-C
ARIES40RMP-C
ARIES40TMP-C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aries C Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces Aries C Series

  • Page 1 Installation and Operation Instructions Aries™ -C Series Millivolt Direct-Vent Gas Fireplaces P/N 900921-00 REV. E 06/2019 Models Ce manuel est disponible en francais, simplement ARIES35RMN-C ARIES35TMN-C ARIES40RMN-C ARIES40TMN-C en faire la demande. Numéro de la pièce 900921-02 ARIES35RMP-C ARIES40RMP-C ARIES40TMP-C ARIES35TMP-C Report No.
  • Page 2: Safety And Your Fireplace

    Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 35” Log Set 40” / 45” Log Set THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (bag in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate 35” Models 18,000 14,500 16,000 13,000 40”...
  • Page 10 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sections 4.00 through 8.00.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 MINIMUM CLEARANCES TO COMBUSTIBLES Table 8 - Minimum Clearances * 1-1/2” (38mm) to wrapper Fireplace And Vent Clearances Back *** 0” (0 mm) to Spacers The fireplace is approved with zero clearance to combustible materials 1/2”...
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Figure 5 - Combustible Side Clearances Figure 6 - Mantel Height At 6” minimum side wall clearance, Mantel depth Top View of a combustible wall 16 (407) Fireplace can project to any length.
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Check local codes for more restrictive installation.
  • Page 18 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Table 10 - Fireplace Framing Specifications Model Framing NOTE: Dimension “D” is the construction to be 10-1/2 required framing depth when 35-7/8 36-1/4 38-3/4 18-1/2 23-3/8 2 x 4, or larger. 35”...
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 7) . 2.
  • Page 20: Determine Vent Setup In The Combination Venting Unit

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 (for 45” models only) Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with round outer flue covers and inner flue cover plates installed that will require removal before connecting the vent pipe.
  • Page 21: Rough In The Electrical Supply, If Needed

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Rough in the Electrical Supply, if Needed As necessary, rough in the fireplace electrical supply per NEC and local codes. Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2”...
  • Page 22: Vent System Preparation

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Install The Rock/Stone Stop Kit (continued) 2. Place Top trim piece and hood that is included with façade on unit and install using three screws (see Figure 11B). 3.
  • Page 23: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figures 12 and 13C . 3.
  • Page 24 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Connecting the Vent Pipe Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist ® lock connections (Figures 15 - 16, Page 24) . All of the fireplaces covered in this document are fitted with collars having locking inclined channels.
  • Page 25 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 26: Install The Vent System

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, • 1” (26 mm) from all sides attic, ceiling insulation, etc.). For all vertical runs: NOTE: Attic insulation shield (H3907, see Page 49) must be •...
  • Page 27 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 24-25 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 28 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 24 for more information. 8.
  • Page 29 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 30 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex ® , use ceiling firestop/ Ceiling firestop/ spacer SF4.5VF.
  • Page 31 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 32 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 33 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Figure 25 - Installing the Horizontal Termination Installing the Horizontal Termination, SV4.5HT-2 To help minimize water infiltration Typical Firestop/Spacer (SV4.5HF) shown (all models) or SV4.5HTSS (35” models only) it is recommended that the Fire- Termination on the exterior side of the wall.
  • Page 34 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 35 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 Flex, 7.62 1.524 Flex, Install the U-shaped vent restrictor in any vent run with more than 4 ft of vertical rise.
  • Page 36 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum feet meters feet meters feet meters Wall firestop/spacer 1.524 0.610 0.305 Wall Firestop/Spacer SV4.5HF ** SV4.5HF** 3.048...
  • Page 37 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required. ®...
  • Page 38: Complete The Field Wiring

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 f. Install three (3) sheet metal screws 120° apart through the flexible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection. 3.
  • Page 39 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 1. If installing an ON/OFF wall switch or thermostat, mount it in a convenient location on a wall near the fireplace. 2. Wire the control switch within the millivolt control circuit using the 15 ft of 2-conductor wire supplied with the unit (Figure 31).
  • Page 40: Connect The Gas Line

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Figure 30 - Wiring Diagram—Junction Box Green Ground - Green White Neutral - White 120 VAC - Black Black (Power Junction Box Supply Unswitched) Tab Intact J-BOX / RECEPTACLE WIRING 120V, 60HZ, 1PH Broken Hot Side of...
  • Page 41 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Access the Control Compartment See Page 54 for instructions on Accessing the Control Compartment. Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications).
  • Page 42: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Verify Proper Fireplace Operation 1. With the gas line installed, inspect the system before closing the front of the unit. 2. Follow the pilot lighting instructions: • Millivolt Systems (Pages 71-72) NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air.
  • Page 43: Optional Accessory: Install The Firebox Liners

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Accessory: Install the Firebox Liners 1. Install the Firebox Liners (see Page 54). Install the Logs, and Glowing Embers 1. See Pages 57 - 61 for instructions on Installing the logs, and glowing embers. Install the Glass Door 1.
  • Page 44 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Figure 33 - Air Shutter Adjustment Rod Table 28 - Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment Adjustment Set-Screw If air shutter is Flame will Air shutter gap should be increased Adjustment...
  • Page 45: Install The Hood

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Install the Hood after fireplace is cool Figure 35 - Hood NOTE: All models must have a hood installed prior to operation. NOTE: Hood is slotted and has some adjustment incase hood is not entirely flat.
  • Page 46 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Facades Figure 36A - Facade Installation NOTE: It is recommended to use the remote when using Craftsman, Artisan, and Reflection facades as the lower compartment area will facade be harder to access.
  • Page 47: Install The Finishing Materials

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Barrier Assembly Replacement (Craftsman, Artisan, and Figure 36D - Bend Retaining TAB UP Reflection) - See Figure 36C through 36E If the screen mesh barrier gets damaged it shall be replaced prior Retaining Tab to operation of the fireplace.
  • Page 48 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 49: Installation Accessories

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. ® Listed Secure Vent Components Catalog Catalog...
  • Page 50 Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 ® Listed Secure Vent Components Catalog Catalog Model Description Model Description Number Number 96K93 SV4.5SU Support Strap 77L76 SV4.5E45 45° Elbow Horizontal Riser Kit, 14”(see 99L02 SV4.5HRK14 750146M) 77L77 SV4.5E90 90°...
  • Page 51: Gas Conversion Kits

    Innovative Hearth Products Installation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 52: Operation

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 53 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and...
  • Page 54: Accessing Control Compartment And Facade Removal

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 55 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing the Firebox Liners (Optional Kit) KIT CONTENTS Affected Fireplace Models 1 ea. Set of 4 Hand Bend Brackets 35" , 40" and 45" direct- 1 ea. Set of Optional Fiber Panels vent fireplace models offered with 1 ea.
  • Page 56 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Bracket Bracket Figure 39C - Insert Bent Bracket Bracket Example of Pre-Bent Bracket Before Insertion Insert Top Leg Of Bracket Between Lintel And Top Panel Bottom Figure 39D Figure 39F - Brackets Installed Bracket Figure 39E - Showing Lintel...
  • Page 57 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Install the Logs and Glowing Embers WARNING • Turn OFF all gas and electricity to the appliance before installing the embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 58 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing the Aries™ -C 35 Series Log Set The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting.
  • Page 59 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing the Aries™ -C 35 Series Log Set (continued) 6. Install right rear log (4) (Figure 44). This log should be placed as far to the right as the slot allows. 7.
  • Page 60 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing the Aries™ -C 40/45 Series Log Set The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting.
  • Page 61 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing the Aries™ -C 40/45 Series Log Set (continued) 6. Install the twig log (5) (Figure 51). This log rests on the left rear log and the grate. 7.
  • Page 62 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 63 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 64: Maintenance

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 MAINTENANCE Refer to the Maintenance Schedule on Page 66 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 65 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 66 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and Qualified Service Technician Inspect valve and ensure it is properly Controls...
  • Page 67: Accessory Components

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 ACCESSORY COMPONENTS Firebox Liner Kits (Required Option) Firebox Liner Kits (continued) Termination Shroud (fits H1968) Liner Kit Includes ember strip Deluxe Termination Guard (fits 94L10 and H1968) Heritage Brown Herringbone Square Termination Guard Heritage Brown Stacked (For use with the small...
  • Page 68 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Thermostatic or Manual modes Wall Thermostat Manual or up to 3 hr Countdown Timer modes • LCD Display • Wall surface mounted • Up to 9 hour Count down Timer •...
  • Page 69 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 OFF/ON Wall Switch Kit Variable Speed Wall Switch Kit Unit-Mountable Rocker Switch Kit The OFF/ON wall switch kit can be used to control The variable speed wall switch kit provides This rocker switch kit can be installed directly the operation of the fireplace burner or blower.
  • Page 70 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 ACCESSORY COMPONENTS (continued) Facade Kits (Required Option) Cat. No. Model Description Used on F3567 FCFBK35T Facade - Classic Frame, Black 35 Trad F3570 FRBK35T Facade - Reflection, Black 35 Trad F3573 FRWC35T Facade - Reflection, Warm Chestnut 35 Trad...
  • Page 71: Lighting Instructions

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 LIGHTING INSTRUCTIONS, MILLIVOLT - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 72 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 LIGHTING INSTRUCTIONS, MILLIVOLT - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 73: Troubleshooting

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 74: Replacement Parts

    Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 REPLACEMENT PARTS Cat. No. Model Description Cat. No. Model Description F3738 ARIES35TMN-C Aries 35” top flue, MV Nat takes facade F3747 ARIES40TMP-C Aries 40” top flue MV LP takes facade F3739 ARIES35TMP-C Aries 35”...
  • Page 75 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 REPLACEMENT PARTS (continued) 35” Models 40” Models Description Catalog Number Catalog Number Glass Door F1841 F1842 Millivolt Pilot Assembly, Natural Gas 69L17 69L17 Millivolt Pilot Assembly, Liquid Propane 69L18 69L18 Millivolt Piezo Igniter...
  • Page 76 Innovative Hearth Products Operation Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 77: Warranty

    Innovative Hearth Products Astria Brand Gas Fireplace ® Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria ® brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The product body, firebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 78 Innovative Hearth Products Installation and Operation Instructions Aries™ -C Series Direct-Vent Gas Fireplaces 900921-00E, 06/2019 Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents