TABLE 5
Superheat Charging Table
(Superheat Entering Suction Service Valve)
OUTDOOR
INDOOR COIL ENTERING AIR (
0
TEMP (
F)
50
52
54
56
58
60
55
9
12
14
17
20
23
60
7
10
12
15
18
21
65
--
6
10
13
16
19
70
--
--
7
10
13
16
75
--
--
--
6
9
12
80
--
--
--
--
5
85
--
--
--
--
--
90
--
--
--
--
--
95
--
--
--
--
--
100
--
--
--
--
--
105
--
--
--
--
--
110
--
--
--
--
--
115
--
--
--
--
--
- Do not attempt to charge system under these conditions of
refrigerant slugging may occur.
TABLE 6
Required Suction Tube Temperature (
(Entering Suction Service Valve)
SUPERHEAT
SUCTION PRESSURE AT SERVICE PORT (psig)
0
TEMP (
F)
61.5
64.2
67.1
70.0
0
35
37
39
41
2
37
39
41
43
4
39
41
43
45
6
41
43
45
47
8
43
45
47
49
10
45
47
49
51
12
47
49
51
53
14
49
51
53
55
16
51
53
55
57
18
53
55
57
59
20
55
57
59
61
22
57
59
61
63
24
59
61
63
65
26
61
63
65
67
28
63
65
67
69
30
65
67
69
71
32
67
69
71
73
34
69
71
73
75
36
71
73
75
77
38
73
75
77
79
40
75
77
79
81
0
F) WET-BULB
62
64
66
68
70
72
74
76
26
29
32
35
37
40
42
45
24
27
30
33
35
38
40
43
21
24
27
30
33
36
38
41
19
21
24
27
30
33
36
39
15
18
21
24
28
31
34
37
8
12
15
18
21
25
28
31
35
--
8
11
15
19
22
26
30
33
--
5
9
13
16
20
24
27
31
--
--
6
10
14
18
22
25
29
--
--
--
8
12
15
20
23
27
--
--
--
5
9
13
17
22
26
--
--
--
--
6
11
15
20
25
--
--
--
--
--
8
14
18
23
0
F)
73.0
76.0
79.2
82.4
85.7
43
45
47
49
51
45
47
49
51
53
47
49
51
53
55
49
51
53
55
57
51
53
55
57
59
53
55
57
59
61
55
57
59
61
63
57
59
61
63
65
59
61
63
65
67
61
63
65
67
69
63
65
67
69
71
65
67
69
71
73
67
69
71
73
75
69
71
73
75
77
71
73
75
77
79
73
75
77
79
81
75
77
79
81
83
77
79
81
83
85
79
81
83
85
87
81
83
85
87
89
83
85
87
89
91
Superheat Charging Table
(Superheat Entering Suction Service Valve)
OUTDOOR
INDOOR COIL ENTERING AIR (
0
TEMP (
C)
10
11.1 12.2
13.3
12.8
5
6.7
7.8
9.4
15.5
3.9
5.6
6.7
8.3
18.3
--
3.3
5.8
7.2
21.1
--
--
3.9
5.6
23.9
--
--
--
3.3
26.7
--
--
--
--
29.4
--
--
--
--
32.2
--
--
--
--
36.0
--
--
--
--
37.8
--
--
--
--
40.6
--
--
--
--
43.3
--
--
--
--
46.1
--
--
--
--
- Do not attempt to charge system under these conditions or
refrigerant slugging may occur.
Required Suction Tube Temperature (
(Entering Suction Service Valve)
SUPERHEAT
SUCTION PRESSURE AT SERVICE PORT (KPaG)
0
TEMP (
K)
424
443
463
483
0
1.7
2.8
3.9
5
1.1
2.8
3.9
5
6.1
2.2
3.9
5
6.1
7.2
3.3
5
6.1
7.2
8.3
4.4
6.1
7.2
8.3
9.4
5.6
7.2
8.3
9.4
10.6
6.7
8.3
9.4
10.6
11.7
7.8
9.4
10.6
11.7
12.8
8.9
10.6
11.7
12.8
13.9
10.0
11.7
12.8
13.9
15
11.1
12.8
13.9
15
16.1
12.2
13.9
15
16.1
17.2
13.3
15
16.1
17.2
18.3
14.4
16.1
17.2
18.3
19.4
15.6
17.2
18.3
19.4
20.6
16.7
18.3
19.4
20.6
21.7
17.8
19.4
20.6
21.7
22.8
18.9
20.6
21.7
22.8
23.9
20.0
21.7
22.8
23.9
25
21.2
22.8
23.9
25
26.1
22.2
23.9
25
26.1
27.2
0
C) WET-BULB
14.4 15.6
16.7
17.8
18.9
20
21.1
11.1 12.8
14.4
16.1
17.8 19.4
20.6
10
11.7
13.3
15
16.7 18.3
19.4
8.9
10.6
11.7
13.3
15
16.7
18.3
7.2
8.9
10.6
11.7
13.3
15
16.7
5
6.7
8.3
10
11.7 13.3
15.6
2.8
4.4
6.7
8.3
10
11.7
13.9
--
--
4.4
6.1
8.3
10.6
12.2
--
--
2.8
5
7.2
8.9
11.1
--
--
--
4.4
5.6
7.8
10
--
--
--
--
3.3
6.7
8.3
--
--
--
--
2.8
5
7.2
--
--
--
--
--
3.3
6.1
--
--
--
--
--
--
4.4
0
C)
503
524
546
568
591
6.1
7.2
8.3
9.4
10.6
7.2
8.3
9.4
10.6
11.7
8.3
9.4
10.6
11.7
12.8
9.4
10.6
11.7
12.8
13.9
10.6
11.7
12.8
13.9
15
11.7
12.8
13.9
15
16.1
12.8
13.9
15
16.1
17.2
13.9
15
16.1
17.2
18.3
15
16.1
17.2
18.3
19.4
16.1
17.2
18.3
19.4
20.6
17.2
18.3
19.4
20.6
21.7
18.3
19.4
20.6
21.7
22.8
19.4
20.6
21.7
22.8
23.9
20.6
21.7
22.8
23.9
25
21.7
22.8
23.9
25
26.1
22.8
23.9
25
26.1
27.2
23.9
25
26.1
27.2
28.3
25
26.1
27.2
28.3
29.4
26.1
27.2
28.3
29.4
30.6
27.2
28.3
29.4
30.6
31.7
28.3
29.4
30.6
31.7
32.8
22.2 23.3
24.4
22.2 23.3
25
21.1 22.2
23.9
20
21.1
22.8
18.3
20
21.7
17.2 18.9
20.6
15.6 17.2
19.4
14.4 16.7
18.3
13.3
15
17.2
12.2 13.9
16.1
11.1 12.8
15
9.40 12.2
14.4
8.3
11.1
13.9
7.8
10
12.8
8