7.5
Chiseling
6
CAUTION
Risk of injury Loss of control over the chisel direction.
▶ Do not operate the tool when the selector switch is set to "Chisel positioning". Turn the function selector
switch until it engages in the "Chiseling"
▶ Set the function selector switch to the "Chiseling" position
7.6
Removing the accessory tool
WARNING
Risk of injury! The tool becomes hot as a result of use.
▶ Wear protective gloves when changing the tool.
1. Pull the accessory tool retaining bar back as far as it will go.
2. Remove the accessory tool.
8
Care and maintenance
WARNING
Electric shock hazard! Attempting care and maintenance with the supply cord connected to a power outlet
can lead to severe injury and burns.
▶ Always unplug the supply cord before carrying out care and maintenance tasks.
Care
Carefully remove any dirt that may be adhering to parts.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
these may attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries including
burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not operate the product if signs of damage are found or if parts malfunction. Have it repaired
immediately by Hilti Service.
After cleaning and maintenance, fit all guards or protective devices and check that they function correctly.
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with the product can be found at your
local Hilti Store or online at: www.hilti.group.
8.1
Replacing the dust shield
1. Pull the chuck back and remove the dust cap.
2. Clean the chuck.
3. Slip the new dust cap on to the chuck.
8.2
Changing chuck
CAUTION
Risk of injury! The depth gauge, if fitted but not used, might hinder the operator.
▶ Remove the depth gauge from the tool.
8