Check List For Troubleshooting - tams elektronik RailCom RCD-2 Manual

2-fold railcom detector with integrated 2-fold track occupancy indicator and 8 switching outputs
Table of Contents

Advertisement

English

10. Check list for troubleshooting

Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
!
Possible cause: one or more components are soldered incorrectly.
à In case you have mounted the module from a kit, perform a
visual check (à section 7.) and if necessary, remedy the faults.
Otherwise send in the module for repair.
When passing the sectioning point between two booster sections a
short circuit occurs.
Possible cause: The two connections of the detector to the rail
(interrupted
reversed. à Check and alter the connections.
Possible cause: The two connections of the booster / the detectors
(interrupted
consistent. à Check and alter the connections.
The RailCom messages are displayed incorrectly and / or very slowly
at the connected display devices.
Possible cause: Interferences in the RailCom data bus. à Connect
the distortion resistors according to fig. 4 to the detector.
An accessory display device assigned to the RCD-2 does not show data.
Possible cause: The RCD-2 and the display device have not been
programmed to the same address. à Program the adresses of the
two devices anew.
Possible cause: The connection A of the RCD-2 is connected to the
connection B of the display device (or the other way round).
à Exchange the connections A and B at one of the devices.
Possible cause: The booster connected to the controlled rail section is
switched off or does not supply the RailCom cutout. à Check the booster.
Page 36
conductor
/
conductor
/
continuous
conductor)
continuous
have
conductor)
are
RCD-2
been
not

Advertisement

Table of Contents
loading

This manual is also suitable for:

45-0102545-0102645-01027

Table of Contents