tams elektronik RailCom RCD-2 Manual page 35

2-fold railcom detector with integrated 2-fold track occupancy indicator and 8 switching outputs
Table of Contents

Advertisement

RCD-2
Allocation of the outputs to further locomotive addresses
In order to allocate further outputs to the detectors and the locomotive
address groups proceed as described in the section before.
Name of CVs CV no.
Allocation of
the outputs
to the
detectors
and
locomotive
addresses
Setting the switching times of the outputs
Name of CVs CV no.
Switching
times of the
outputs
44 and 46
54 and 56
64 and 66
...
274 and 276 Detector 1 / locomotive address group 13
284 and 286 Detector 2 / locomotive address group 13
Input value
(Default
value)
By setting the switching time you determine how long
the output is supplied with current. Increasing the
input value by 1 prolongs the switching time by 65,5
msec. The longest switching time to be set is 16,5 sec.
10
1 ... 255 (4)
11
1 ... 255 (4)
12
1 ... 255 (4)
...
17 or 3
1 ... 255 (4)
Remarks and tips
Detector 2 / locomotive address group 1
Detector 1 / locomotive address group 2
Detector 2 / locomotive address group 2
...
Remarks and tips
output 1
output 2
output 3
...
output 8
CV#3 = alternative CV
English
Page 35