Programming The Rcd-2 - tams elektronik RailCom RCD-2 Manual

2-fold railcom detector with integrated 2-fold track occupancy indicator and 8 switching outputs
Table of Contents

Advertisement

RCD-2
LED-display
When the LED on the RCD-2 is illuminated, the detector is ready for
operation. When changing into the programming mode the LED starts
flashing continuously.

9. Programming the RCD-2

By programming the configuration variables (CVs) you set separately
for the two detectors of the RCD-2:
their addresses;
which locomotive addresses release a switching operation in the
controlled rail section and
which of the 8 outputs is switched with a particular locomotive
address.
Here you have to program on main (POM) for the RCD-2, according to
the programming of locomotive decoders. With control units not
supporting programming on main, you cannot program the RCD-2.
Choose any DCC locomotive address on your control unit and perform
the programming for this address. Make sure not to use an address of a
locomotive on the layout.
In order to change into the programming mode insert the jumper
included in the package onto the 2-pole solder pin beside the LED. The
LED which was illuminated till then starts continuously flashing.
In the following list you find all configuration variables to be set. The
default values are the values in state of delivery which are restored
after a reset.
Please note: With some control units it is not possible to program the
configuration variables CV#1 and CV#17 by POM. With these control
units use the listed alternative CVs.
English
Page 29

Advertisement

Table of Contents
loading

This manual is also suitable for:

45-0102545-0102645-01027