tams elektronik RailCom RCD-2 Manual page 34

2-fold railcom detector with integrated 2-fold track occupancy indicator and 8 switching outputs
Table of Contents

Advertisement

English
Name of CVs
Allocation of
the outputs to
detector 1
and
locomotive
address group
1
Example 1: Output 1, 5 and 7 are switched as soon as a locomotive
belonging to address group 1 (detector 1) is pulling into track section 1.
CV#34 = 1+16+64 = 81 | CV#36 = 0
Example 2: Output 1, 5 and 7 are switched as soon as a locomotive not
belonging to address group 1 (detector 1) is pulling into track section 1.
CV#34 = 0 | CV#36 = 1+16+64 = 81
Page 34
CV
Input value
no.
(Default
value)
34
0 ... 255 (0)
36
0 ... 255 (0)
Remarks and tips
Allocation of the outputs 1 - 8
Inverted allocation of the
outputs 1 - 8
output 1
output 2
output 3
output 4
output 5
output 6
output 7
output 8
RCD-2
1
2
4
8
16
32
64
128