English
6. Technical specifications
Attention: As a power supply for the RCD-2 you should not use the
transformer supplying the digital control. If possible you should use a
separate transformer supplying only the RailCom components on your
layout.
Supply voltage
Digital format
Feedback log
Number of sections controlled by
RailCom
Number of outputs of track occupancy
indicators
max. current / output
Number of switching outputs
max. current / switching output
max. Strom for switching outputs
Current consumption without connected
loads approx.
Protected to
Ambient temperature in use
Ambient temperature in storage
Comparative humidity allowed
Dimensions of the PCB (approx.)
Dimensions including housing (approx.)
Weight of the assembled board (approx.)
Weight including housing (approx. )
Page 14
12 - 18 Volt d.c.
or a.c. voltage
DCC
RailCom
2
2
100 mA
8
300 mA
500 mA
100 mA
IP 00
0 ... +60 °C
-10 ... +80 °C
max. 85 %
72 x 82 mm
100 x 90 x 35 mm
75 g
123 g
RCD-2