Removal Of Battery From The Motorcycle; Battery Maintenance - Royal Enfield Continental GT Owner's Manual

Euro vi
Hide thumbs Also See for Continental GT:
Table of Contents

Advertisement

Minor Maintenance Tips

REMOVAL OF BATTERY FROM THE MOTORCYCLE

(-)
TERMINAL
The battery is located on the left side of the
motorcycle.
Ensure the motorcycle is parked on its center stand,
in a well-ventilated area.
Ensure the ignition switch and engine stop switch
are in OFF position.
Unlock and remove the battery cover.
Remove the battery car rier bracket by loosening
the two screws.
Pull the battery out slightly from the carrier and
Disconnect the -VE terminal FIRST and the +VE
terminal next.
Remove the battery from the carrier.

BATTERY MAINTENANCE

Care Maintenance :
(+)
Clean the battery well using a soft and wet cloth.
TERMINAL
Inspect the battery carefully for any deformation
of its housing. If found deformed, replace the
battery immediately
Clean the terminals using a soft wire brush to
remove any oxidations.
Check the electrolyte level to see if it is between
MAX and MIN lines
If necessary top up ONLY with pure and clean
distilled water till the level is between the MAX
and MIN lines. DO NOT OVERFILL as it will
overflow through the vent hole of the battery
and cause irreparable damage to the motorcycle
parts.
Check and ensure the specific gravity of the
electrolyte and the terminal voltage are as per
the recommendations of the battery manufacturer.
Always get the battery tested
authorized battery service center OR Royal
Enfield service center.
59
through an