Table 8 - High Performance Turbine (Hpt) Meters - Neptune TRICON E Installation And Maintenance Manual

Table of Contents

Advertisement

Maximum
Continuous
Meter Size (In)
Flow Rate
(gpm)
160
2
200
3
450
4
1,200
6
2,500
8
4,000
10
6,500
12
8,000
16
13,500
20
22,000
*For the High Resolution Output of the TRICON/E2 transmitters, multiply these values by 9 and for the
TRICON/E3, multiply these values by 10.
TRICON ® E/E2/E3 Installation and Maintenance Guide
Table 8  – High Performance Turbine (HPT) Meters
Minimum Flow
Number of Pulses per
Rate (gpm)
4
6.09500
4
6.09500
5
11.20000
10
7.55600
20
0.72730
35
0.75560
50
0.75560
120
0.75560
200
0.07556
300
0.07556
Pulse Output @
Maximum Flow
Gallon*
Rate (Hz)*
16.25
20.32
84.00
151.1
30.30
50.37
81.86
100.75
17.00
27.71
Chapter 2: Specifications
Flow Range of
4-20MA
Output (gpm)
0–160
0–200
0–450
0–1,200
0–3,000
0–4,000
0–6,500
0–8,000
0–13,500
0–22,000
7