Chapter 3 Specifications and Performance Data
Environmental Conditions
Electrical Specifications (TRICON E3 Models)
Parameter
Vol
Low Digital Pulse Output Voltage
Voh
High Digital Pulse Output Voltage
Current @ Vol
Iol
Ioh
Current @ Voh
t
l-h
Output Rise Time
1
r
t
h-l
1
Output Fall Time
f
Measured with R
=2.4KΩ and C
1
L
TRICON/E/E2/E3 Transmitter Installation and Maintenance Guide
This chapter will provide you will the electrical specifications and the
performance data for the models of the TRICON transmitter.
Operating Temperature
Storage Temperature
Operating Humidity
Table 3.1 Pulse Outputs (over 0-70°C operating temp)
Description
Minimum
=50pF.
L
32° to 158°F ( 0° to 70°C)
-40° to 185°F (-40° to 85°C)
0 to 95% RH, non-condensing
Typical
—
0.4
8.5
V
–1.0V
DCIN
—
-10
—
+10
—
—
—
—
Maximum
Units
—
V
12
V
—
mA
—
mA
2
uS
2
uS
3-1