Chapter 2: Specifications; Environmental Conditions; Electrical Specifications (Tricon ® /E3 Model); Table 1 - Pulse Outputs (Over 0-70° C Operating Temperature) - Neptune TRICON E Installation And Maintenance Manual

Table of Contents

Advertisement

This chapter provides the electrical specifications and the performance data for all models of
the TRICON
The TRICON/E3 is not submersible. Neptune does not recommend installing the
TRICON/E3 in a pit environment.

Environmental Conditions

Operating Temperature: 32° to +158° F (0° to +70° C)
l
Storage Temperature: –40° to +185° F (–40° to +85° C)
l
Operating Humidity: 0 to 95% RH, non-condensing
l
Electrical Specifications (TRICON
The following tables define the electrical specifications for the TRICON/E3 model.
Table 1  – Pulse Outputs (over 0-70° C Operating Temperature)
Parameter
Vol
Low Digital Pulse Output Voltage
Voh
High Digital Pulse Output Voltage
Iol
Current @ Vol
Ioh
Current @ Voh
*t
l-h
Output Rise Time
r
*t
h-l
Output Fall Time
f
*
Measured with R
=2.4KΩ and C
L
TRICON ® E/E2/E3 Installation and Maintenance Guide
®
transmitter.
®
/E3 Model)
Description
=50pF.
L

Chapter 2: Specifications

Minimum
Typical
N/A
0.4
8.5
VDCIN–1.0V
N/A
–10
N/A
+10
N/A
N/A
N/A
N/A
Maximum
Units
N/A
V
12
V
N/A
mA
N/A
mA
2
uS
2
uS
3

Hide quick links: