Parameter list
Pr.
Name
Output interruption
576
0 to 590Hz
detection level
Output interruption
577
900 to 1100%
cancel level
Traverse function
592
0 to 2
selection
Maximum amplitude
593
0 to 25%
amount
Amplitude
594
compensation amount
0 to 50%
during deceleration
Amplitude
595
compensation amount
0 to 50%
during acceleration
Amplitude acceleration
596
0.1 to 3600s
time
Amplitude deceleration
597
0.1 to 3600s
time
X10 terminal input
599
0,1
selection
First free thermal
0 to 590Hz,
600
reduction frequency 1
9999
First free thermal reduction
601
1 to 100%
ratio 1
First free thermal
0 to 590Hz,
602
reduction frequency 2
9999
First free thermal
603
1 to 100%
reduction ratio 2
First free thermal
0 to 590Hz,
604
reduction frequency 3
9999
Power failure stop
606
external signal input
0, 1
selection
Motor permissible load
607
110 to 250%
level
Second motor
110 to 250%,
608
permissible load level
9999
PID set point/deviation
609
1 to 5
input selection
PID measured value
610
1 to 5
input selection
Acceleration time at a
0 to 3600s,
611
restart
9999
Reverse rotation
617
excitation current low-
0 to 300%, 9999 9999
speed scaling factor
Cumulative pulse clear
635
0 to 3

signal selection
Cumulative pulse
636
0 to 16384

division scaling factor
Control terminal
option—Cumulative
637
0 to 16384

pulse division scaling
factor
Cumulative pulse
638
0 to 3

storage
Brake opening current
639
0, 1
selection
Brake operation
640
0, 1
frequency selection
Second brake
641
sequence operation
0, 7, 8, 9999
selection
Second brake opening
642
0 to 30Hz
frequency
Second brake opening
643
0 to 400%
current
Second brake opening
644
0 to 2s
current detection time
Second brake operation
645
0 to 5s
time at start
Second brake operation
646
0 to 30Hz
frequency
Second brake operation
647
0 to 5s
time at stop
Second deceleration
648
detection function
0, 1
selection
Second brake opening
650
0, 1
current selection
Second brake operation
651
0, 1
frequency selection
Speed smoothing
653
0 to 200%
control
Speed smoothing cutoff
654
0 to 120Hz
frequency
Analog remote output
655
0, 1, 10, 11
selection
656
Analog remote output 1
657
Analog remote output 2
800 to 1200%
658
Analog remote output 3
659
Analog remote output 4
Increased magnetic
660
excitation deceleration
0, 1
operation selection
Magnetic excitation
661
0 to 40%, 9999 9999
increase rate
20
INVERTER FUNCTION SETTING
Setting
Initial
Pr.
range
value
Increased magnetic
0Hz
662
excitation current level 0 to 300%
Control circuit
1000%
663
temperature signal
output level
0
Regeneration
665
avoidance frequency
10%
gain
Power failure stop
668
frequency gain
10%
User parameter auto
675
storage function
selection
10%
679
Second droop gain
Second droop filter time
5s
680
constant
Second droop function
5s
681
activation selection
Second droop break
0
682
point gain
Second droop break
9999
683
point torque
Tuning data unit
100%
684
switchover
686
Maintenance timer 2
9999
Maintenance timer 2
687
warning output set time 0 to 9998, 9999 9999
100%
688
Maintenance timer 3
Maintenance timer 3
9999
689
warning output set time 0 to 9998, 9999 9999
Deceleration check time 0 to 3600s,
690
1
Second free thermal
692
reduction frequency 1
150%
Second free thermal
693
9999
reduction ratio 1
Second free thermal
694
reduction frequency 2
2
Second free thermal
695
reduction ratio 2
3
Second free thermal
696
9999
reduction frequency 3
699
Input terminal filter
Maximum motor
702
frequency
Induced voltage
706
0
constant (phi f)
707
Motor inertia (integer)
1
711
Motor Ld decay ratio
712
Motor Lq decay ratio
1
Starting resistance tuning
717
compensation
Starting magnetic pole
0
721
position detection pulse
width
0
724
Motor inertia (exponent)
Motor protection current
725
0
level
Second motor induced
738
voltage constant (phi f)
0
Second motor Ld decay
739
ratio
3Hz
Second motor Lq decay
740
ratio
130%
Second starting
741
resistance tuning
0.3s
compensation
Second motor magnetic
0.3s
742
pole detection pulse width
6Hz
Second motor
743
maximum frequency
0.3s
Second motor inertia
744
(integer)
Second motor inertia
0
745
(exponent)
Second motor
746
0
protection current level
0
Second PID action
753
0
selection
20Hz
Second PID control
0
754
automatic switchover
frequency
1000%
Second PID action set
1000%
755
point
1000%
Second PID
756
1000%
proportional band
Second PID integral
757
0
time
Second PID differential
758
time
759
PID unit selection
Setting
Initial
Name
range
value
100%
0 to 100°C
0°C
0 to 200%
100%
0 to 200%
100%
1, 9999
9999
0 to 100%
9999
0 to 1s
9999
0 to 2, 10, 11,
9999
20 to 22
0.1 to 100%
9999
0.1 to 100%
9999
0, 1
0
0 (1 to 9998)
0
0 (1 to 9998)
0
1s
9999
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
5 to 50ms, 9999 9999
0 to 400Hz,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
10 to 999, 9999 9999
0 to 100%, 9999 9999
0 to 100%, 9999 9999
0 to 200%, 9999 9999
0 to 6000μs,
10000 to
9999
16000μs, 9999
0 to 7, 9999
9999
100 to 500%,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
0 to 100%, 9999 9999
0 to 100%, 9999 9999
0 to 200%, 9999 9999
0 to 6000μs,
10000 to
9999
16000μs, 9999
0 to 400Hz,
9999
9999
10 to 999, 9999 9999
0 to 7, 9999
9999
100 to 500%, 9999 9999
0, 10, 11, 20, 21,
50, 51, 60, 61, 70,
71, 80, 81, 90, 91,
100, 101, 1000,
0
1001, 1010, 1011,
2000, 2001, 2010,
2011
0 to 590Hz,
9999
9999
0 to 100%, 9999 9999
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0.01 to 10.00s,
9999
9999
0 to 43, 9999
9999
Setting
Pr.
Name
range
Pre-charge fault
760
0, 1
selection
761
Pre-charge ending level
0 to 100%, 9999 9999
762
Pre-charge ending time
0 to 3600s, 9999 9999
Pre-charge upper detection
763
0 to 100%, 9999 9999
level
764
Pre-charge time limit
0 to 3600s, 9999 9999
Second pre-charge fault
765
0, 1
selection
Second pre-charge
766
0 to 100%, 9999 9999
ending level
Second pre-charge
767
0 to 3600s, 9999 9999
ending time
Second pre-charge
768
0 to 100%, 9999 9999
upper detection level
Second pre-charge time
769
0 to 3600s, 9999
limit
Operation panel monitor
1 to 3, 5 to 14,
774
selection 1
17 to 20, 22 to 36,
Operation panel monitor
38 to 46, 50 to 57,
775
selection 2
61, 62, 64, 67,
71 to 75, 87 to 98,
Operation panel monitor
776
100, 9999
selection 3
4 mA input fault
777
0 to 590Hz, 9999
operation frequency
778
4 mA input check filter
0 to 10s
Operation frequency
779
during communication
0 to 590Hz, 9999
error
Acceleration time in
791
0 to 3600s, 9999
low-speed range
Deceleration time in
792
0 to 3600s, 9999
low-speed range
Pulse increment setting
0.1, 1, 10, 100,
799
for output power
1000kWh
0 to 6, 9 to 14,
Control method
800
20, 100 to 106,
selection
109 to 114
801
Output limit level
0 to 400%, 9999 9999
802
Pre-excitation selection 0, 1
Constant output range
803
torque characteristic
0 to 2, 10, 11
selection
Torque command
804
0 to 6
source selection
Torque command value
805
600 to 1400%
(RAM)
Torque command value
806
600 to 1400%
(RAM,EEPROM)
807
Speed limit selection
0 to 2
Forward rotation speed
808
0 to 400Hz
limit/speed limit
Reverse rotation speed
809
limit/reverse-side speed
0 to 400Hz, 9999
limit
Torque limit input method
810
0, 1, 2
selection
811
Set resolution switchover 0, 1, 10, 11
Torque limit level
812
0 to 400%, 9999
(regeneration)
Torque limit level (3rd
813
quadrant)
Torque limit level (4th
814
quadrant)
815
Torque limit level 2
0 to 400%, 9999
Torque limit level during
816
acceleration
Torque limit level during
817
deceleration
Easy gain tuning
818
1 to 15
response level setting
819
Easy gain tuning selection 0 to 2
820
Speed control P gain 1 0 to 1000%
Speed control integral
821
0 to 20s
time 1
822
Speed setting filter 1
0 to 5s, 9999
823
Speed detection filter 1 0 to 0.1s

Torque control P gain 1
824
(current loop
0 to 500%
proportional gain)
Torque control integral
825
time 1 (current loop
0 to 500ms
integral time)
826
Torque setting filter 1
0 to 5s, 9999
827
Torque detection filter 1 0 to 0.1s
828
Model speed control gain 0 to 1000%
Number of machine end
829
0 to 4096, 9999 9999

encoder pulses
830
Speed control P gain 2 0 to 1000%, 9999 9999
Speed control integral
831
0 to 20s, 9999
time 2
832
Speed setting filter 2
0 to 5s, 9999
833
Speed detection filter 2 0 to 0.1s, 9999

834
Torque control P gain 2 0 to 500%, 9999
Initial
value
0
0
9999
9999
9999
9999
9999
0s
9999
9999
9999
1kWh
20
0
0
0
1000%
1000%
0
60Hz
9999
0
0
9999
9999
9999
9999
9999
9999
2
0
60%
0.333s
9999
0.001s
100%
5ms
9999
0s
60%
9999
9999
9999
9999