Abbreviation
LOCD
Password locked
Er1 to Er4
Parameter write error
Er8
rE1 to rE8
Copy operation error
Err.
RES signal ON or communication circuit fault
OL
Stall prevention (overcurrent)
oL
Stall prevention (overvoltage)
RB
Regenerative brake pre-alarm
TH
Electronic thermal relay function pre-alarm
PS
PU stop
MT1 to MT3
Maintenance signal output
CP
Parameter copy
SL
Speed limit indication
Continuous operation during communication
CF
fault
SA
SA
UF
USB host error
LDF
Load fault warning
HP1
Home position return setting error
HP2
Home position return uncompleted
HP3
Home position return parameter setting error
FN
Fan alarm
E.OC1
Overcurrent trip during acceleration
E.OC2
Overcurrent trip during constant speed
E.OC3
Overcurrent trip during deceleration or stop
Regenerative overvoltage trip during
E.OV1
acceleration
Regenerative overvoltage trip during constant
E.OV2
speed
Regenerative overvoltage trip during
E.OV3
deceleration or stop
Inverter overload trip (electronic thermal relay
E.THT
function)
Motor overload trip (electronic thermal relay
E.THM
function)
E.FIN
Heatsink overheat
E.IPF
Instantaneous power failure
E.UVT
Undervoltage
E.ILF
Input phase loss
E.OLT
Stall prevention stop
E.GF
Output side earth (ground) fault overcurrent
E. SOT
Loss of synchronism detection
E.LUP
Upper limit fault detection
E.LDN
Lower limit fault detection
E.LF
Output phase loss
E.OHT
External thermal relay operation
E.PTC
PTC thermistor operation
E.OPT
Option fault
E.OP1
Communication option fault
E. 1 to E. 3
Option fault
E.PE
Parameter storage device fault
E.PUE
PU disconnection
E.RET
Retry count excess
E.PE2
Parameter storage device fault
E. 5 to E. 7
CPU fault
E.CPU
Operation panel power supply short circuit/
E.CTE
RS-485 terminals power supply short circuit
E.P24
24 VDC power fault
E.CDO
Abnormal output current detection
24
TROUBLESHOOTING
Name
Abbreviation
E.IOH
Inrush current limit circuit fault
E.SER
Communication fault (inverter)
E.AIE
Analog input fault
E.OS
Overspeed occurrence
E.OSD
Speed deviation excess detection
E.ECT
Signal loss detection
E.OD
Excessive position fault
E.MB1 to E.MB7 Brake sequence fault
E.EP
Encoder phase fault
E.EF
External fault during output operation
E. BE
Brake transistor alarm detection
E. USB
USB communication fault
E.11
Opposite rotation deceleration fault
E.13
Internal circuit fault
E.PBT
E.SAF
Safety circuit fault
E.LCI
4 mA input fault
E.PCH
Pre-charge fault
E.PID
PID signal fault
E.16 to E.20
User definition error by the PLC function
E.0
No fault history
RD
Backup in progress
WR
Restoration in progress
If faults other than the above appear, contact your sales