53.1 SPN 630/FMI 14
There are multiple fault descriptions for SPN 630/FMI 14. They are listed with the troubleshooting
solution:
□ CPC failed to download MCM static fault data. Reprogram the CPC with the latest
software release.
□ MCM reporting inconsistent static fault code data. Reprogram the MCM with the latest
software release
□ MCM contains more MUs than the current CPC2 software version is able to store.
Reprogram the CPC with the latest software release.
□ MCM is reporting inconsistent static fault code data. Reprogram the MCM with the latest
software release.