6. Activate the parameter t 06 11 Bobbin Rotation Monitor.
Press the
7. Restart the machine to adopt the settings.

3.2 Testing the SSD

You can use the menu
Control to test the SSD:
Icon
14
button to return to the main screen.
Service >
Multi test >
Description
RFW limit
• Value range: 0.0 - 4.0
• Default value: 1.7
RFW intensity
• Value range: 0.0 - 4.0
• Default value: 1.7
Test the stitch counter hook thread
• Check: Switch to the display Stitch counter hook thread and turn
the bobbin; the counter is incremented with every half turn
Test value of the hook thread stitch counter
• Check: Switch to the display Value hook thread stitch counter and
turn the empty bobbin slowly into the reflecting area.
With the proper setting, the value of the hook thread stitch counter
must be > 1500.
Test the remaining thread monitor signal
Check the signal of the reflecting surface
Test the bobbin rotation counter
• Check: Switch to the display Bobbin rotation counter and turn the
bobbin; the counter is incremented 12 times per turn
Test the value of the bobbin rotation counter
• Check: Switch to the display Value hook thread stitch counter and
turn the empty bobbin slowly into the reflecting area.
With the proper setting, the value of the hook thread stitch counter
must be > 1500.
Navigation >
t 60 09 Test Loop
Additional Instructions D867 - 00.0 - 04/2020