Location Requirements - Whirlpool Cabrio W10164159B Use & Care Manual

Steam fabric care system electric dryer
Table of Contents

Advertisement

Available languages

Available languages

Parts needed:
Check local codes. Check existing electrical supply and venting and
see "Electrical Requirements" and "Venting Requirements" before
purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For information on ordering, please refer to the
"Assistance or Service" section. You may also contact the dealer
from whom you purchased your dryer.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes
dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at least
4 ft (1.22 m) long. The wires that connect to the dryer must end
in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.

Location Requirements

You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer.
See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of
200 lbs (90.7 kg). The combined weight of a companion
appliance should also be considered.
Cold water faucets located within 4 ft (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (138-690 kPa). You
may use the water supply for your washer using the "Y"
connector and short hose (if needed) which are provided.
20-100 psi (138-690 kPa) for best performance.
A level floor with a maximum slope of 1" (25 mm) under entire
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open
fully.
Dryer Dimensions
1
43
/
"
2
(1105 mm)
1
29
/
"
4
(743 mm)
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer.
This dryer has been tested for spacing of 0" (0 mm) clearance on the
sides and rear. Recommended spacing should be considered for the
following reasons:
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and floor
moldings.
Additional spacing should be considered on all sides of the dryer
to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Additional spacing is required if you exhaust out the rear of the
dryer to either the right or left side.
18"*
(457 mm)
1"
1"
29"
(25 mm)
(25 mm)
(737 mm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part 280) or
Standard CAN/CSA-Z240 MH.
22
1
/
"
4
(565 mm)
29"
(737 mm)
14" máx.*
(356 mm)
2
48 in.
*
2
(310 cm
)
24 in.
2
*
(155 cm
2
)
5"
29
1
/
"
4
(127 mm)
(743 mm)
B
C
3"*
(76 mm)
3"*
(76 mm)
5