Location Requirements; Installation Clearances; Dryer Dimensions - Whirlpool WED9500EC Installation Instructions Manual

Gas and electric
Table of Contents

Advertisement

Available languages

Available languages

Parts needed:
(Not supplied with dryer)
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the "Assistance
or Service" section in your "Use and Care Guide."

LOCATION REQUIREMENTS

You will need:
A location allowing for proper exhaust installation.
See "Venting Requirements."
A separate 15 or 20-amp circuit needed for gas dryers and
30-amp circuit needed for electric dryers.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), clothes may not
tumble properly and automatic sensor cycles may not
operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above floor.
Steam models only: Cold water faucets located within 4 ft.
(1.2 m) of the water fill valves, and water pressure of 20-100
psi (137.9-689.6 kPa). You may use the water supply for your
washer using the "Y" connector and short hose which are
provided.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45°F (7°C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.

INSTALLATION CLEARANCES

For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances and
clearances for walls, doors, and floor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

DRYER DIMENSIONS

Front Controls Models
57
/
"
5
8
(1464 mm)
33
/
"
1
2
(851 mm)
1"
11
"
3
/
8
(25 mm)
(289 mm)
Side view
Bottom view:
14
(365 mm)
Rear Controls Models
57
/
"
5
8
(1464 mm)
33
/
"
1
2
(851 mm)
1"
11
/
"
3
8
(25 mm)
(289 mm)
Side view
Bottom view:
14
(365 mm)
NOTE: Most installations require a minimum of 6" (152 mm)
clearance behind dryer for exhaust vent with elbow. See
"Venting Requirements."
Door Opened
29"
Door Closed
(737 mm)
41
/
"
3
8
(1050 mm)
3"
1
/
"
14
/
"
3
1
3
"
5
/
8
2
8
(77 mm)
(35 mm)
(370 mm)
(93 mm)
Back view
8
/
"
1
2
(218 mm)
/
"
3
8
Door Opened
29"
Door Closed
(737 mm)
41
43
/
"
"
11
7
16
16
(1103 mm)
(1103 mm)
3"
1
/
"
14
/
"
3
1
3
/
"
5
8
2
8
(77 mm)
(35 mm)
(370 mm)
(93 mm)
Back view
8
"
/
1
2
(218 mm)
/
"
3
8
5
"
/
7
8
(150 mm)
4
/
"
1
2
(115 mm)
3
/
"
1
2
(93 mm)
5
/
"
7
8
(150 mm)
4
/
"
1
2
(115 mm)
3
/
"
1
2
(93 mm)
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wgd9500ec

Table of Contents