Electrical Requirements - Whirlpool ACE184PT0 Use And Care Manual

Whirlpool air conditioner use & care guide
Table of Contents

Advertisement

Available languages

Available languages

Window Installation
Window opening measurements:
30" to 40" (76.2 cm to 101.6 cm) opening width.
20" (50.8 cm) minimum opening height.
A. 30" (76.2 cm) minimum
B. 20" (50.8 cm) minimum
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Ground wire must be connected to the ground screw located in
the lower right corner of the air conditioner when the air
conditioner is in the cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the flange below the
control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power Supply Cord
Wiring Requirements
4
A
B

Electrical Requirements

115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
Through-the-Wall Installation
The wall opening measurements should be:
Width: 26 " (66.1 cm) plus twice thickness of wood used to
build frame.
Height: 19 " (50.2 cm) plus twice thickness of wood used to
build frame.
Depth: Dimension for depth depends on the wall thickness
and the type of molding.
A
A. 19 " (50.2 cm)
B. 26 " (66.1 cm)
Power Supply Cord
Wiring Requirements
"
(0.6 cm)
"
(1.3 cm)
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.
C
B
D
C
C. Wood thickness
D. Depth
230-volt (207 min. to 253 max.)
0 to 12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
0 to 16 amps
20-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
0 to 24 amps
30-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.

Advertisement

Table of Contents
loading

This manual is also suitable for:

66121560

Table of Contents