Elpumps VP 300 Operating Instructions

Elpumps VP 300 Operating Instructions

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VP 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Elpumps VP 300

  • Page 2: Specifications

    OPERATING INSTRUCTIONS VP 300 type vibration submersible pump (further on: pump) can be used for pumping out subsurface waters (from dug or drilled wells) if the inner diameter of the well is at least 110 mm. When pumping out surface waters (lakes, cisterns, barrels), it must be taken into account that at least 1 m water height from the bottom of the pump must always be provided.
  • Page 3: Safety Regulations

    Bundle ca. each 2 m of the cable, the hose and the suspending wire by means of insulating tape or plastic clamp in such a way that the electric cable does not strain. In drilled wells, apply protective rubber ring for the protection of the pump and the wall of the well.
  • Page 4: Maintenance

    7. MAINTENANCE During the guarantee period any repair can only be performed by the brand’s repair service! Following the guarantee period, you may replace the plunger and the foot valve in your workshop if they fail. In order to do it, release the four external screws which are factory tightened with 6-Nm torque.
  • Page 5 3. Guarantee note 10. DECLARATION ELPUMPS Ltd (21, Szamári Street, Fehérgyarmat, 4900, Hungary) certifies CE conformity of the product and that the pump VP 300 complies with the technical data specified in the data plate and the “Operating instructions”. Water delivery (l/hour)