OPTIONAL ACCESSORIES - UV-C / OZONE
UV-C WATER TREATMENT
WARNING: THE GERMICIDAL ULTRAVIOLET RAYS
ARE HARMFUL TO THE EYES, SKIN.
INTEGRATION:
1. Install the sterilization equipment at an easy to reach well
lit place for effortless observation and maintenance.
2. Lock the clamp on the frame.
3. Insert the chamber with the help of the clamps.
4. Connect to the water supply.
5. Insert the quartz sleeve, sealing ring, lamp.
IMPORTANT: DO NOT TOUCH THE QUARTZ SLEEVE
OR THE SIDES OF THE LAMP, ONLY HOLD IT BY THE
TWO ENDS.
The ultraviolet lamp and the quartz can easily be damaged.
Take care when removing or changing the lamp or the quartz
sleeve.
a. Take off the nut. (2).
b. Carefully slide the quartz sleeve (6) from one end of the
chamber to the other.
c. Slide the sealing ring (5) onto the free end points of the
quartz sleeve.
d. Squeeze the aluminum nut on by hand (2).
e. Slide the lamp (4) into the quartz sleeve.
f. Connect the lamp to the casing.
g. Screw the nut to the chamber, then screw on the water
resistant lid (1) to the nut (2).
h. Open the tap and check if the device is leaking. Repair as
necessary.
I. Plug the device into the electric supply. Use a socket
equipped with a fault circuit interrupter (GFCI).
OZONE DISINFECTION
FILTRATION AND OZONE
In a system without circulation engines the low setting of
the massage engine and the ozone generator will switch on
during filtration. In a circulation type system ozone starts in a
system with circulation engine.
The system is factory programmed for an evening filtration
cycle since energy prices might be lower in the evening
(assuming that the time of day is properly set). The filtration
time and duration are programmable.
A second filtration cycle can be freely entered.
At the start of every filtration cycle the jets and engine start
to clean the pipes and ensure proper water quality.
1- Water resistant lid
2- Aluminum nut
3- Lamp casing, wire outlet
4- Germicidal ultraviolet lamp
5- Rubber sealing ring
6- Quartz sleeve
7- Chamber
8- Pawl
9- Transformer
CHANGING THE LAMP AND SERVICING THE UV
SYSTEM
Important: Do not touch the quartz sleeve or the sides of the
lamp, only hold it by the ends.
1. Unplug the power plug.
2. Shut down and drain the water from the device to lessen
pressure.
3. Take off the PVC lid (1) and unscrew the aluminum nut (2).
4. Carefully pull out the lamp (4) to approximately 5cm from
the chamber (7).
5. Holding the lamp by the end carefully remove the lamp
casing (3) on the free end.
6. Carefully take the lamp out of the chamber.
7. Carefully take off the sealing ring (5) from the end of the
quartz sleeve.
8. Carefully take off the quartz sleeve.
9. To reinstall follow instructions 1 to 8 in reversed order
MAINTENANCE SUGGESTION:
In order for the sterilizer to work properly and with maximal
efficiency the user should perform the following mainte-
nance tasks.
1. Cleaning, changing the quartz sleeve:
a) The quartz sleeve is to be cleaned with a glass cleaner
solution every 6-12 months.
b) The quartz sleeve is to be changed every 24 months.
2. Changing the UV lamp is recommended after 8-9000 op-
erating hours (about 12 months of continuous operation).
3. To acquire interchangeable parts contact our headquar-
ters or the local representatives of our company.
CONTAMINATED WATER
CLEAN
WATER
OZONE MIXER
FILTERED
WATER
OZONE GENERATORTOR
OZONE INJECTOR
WARM WATER
WARM WATER
CIRCULA-
WARM
TION PUMP
WATER
97