OPTIONAL ACCESSORIES - IN.CLEAR (IN SMART TOUCH)
IN.CLEAR OPERATING MODES
IF YOU ARE A USING A SMART TOUCH, PLEASE REFER TO THE USER INTERFACE SECTION TO GET THE IN-
STRUCTIONS ABOUT THE SANITIZATION MODE.
mode selection
wheel:
in.clear icon
MAINTENANCE MODE
Maintenance Mode keeps the bromine bank levels at a
stable and acceptable range when the hot tub is not being
used. Maintenance mode is the "everyday" mode and is
automatically ON when the system is activated. Maintenance
level adjustment changes the rate at which bromine will be
released into the hot tub water.
Finding and setting the right maintenance level will keep
the residual bromine level between 3 and 5 PPM (the rec-
ommended range) when the hot tub is not being used or is
left unused for an extended period of time. Once the proper
maintenance level is determined, keep the same setting
unless the hot tub conditions change (change in water tem-
perature, hot tub location, etc).
Finding the right bromine generation level is a crucial step
for the in.clear system to be stable and effective (see Set
Maintenance Mode).
It is important to note that the in.clear system can ONLY
generate bromine when the water is circulating. If you are
having problems maintaining a stable level of bromine, or de-
termining the proper maintenance level for your hot tub, you
may have to increase the daily filtering time. Longer filtration
produces a more steady level of bromine.
statuts and messages
BOOST MODE
The Boost Mode should be activated every time you use your
hot tub. Boost mode increases the bromine generation rate
to attack pollutants in the water and helps rebuild the neces-
sary residual bromine in the water after each use of the hot
tub. Pollutants are introduced to the water by the bathers,
causing the bromine levels to decrease. Activating the boost
mode when you enter the hot tub will prevent inadequate
bromine levels and will restore your bromine to the proper
residual level.
Finding the right boost level is another crucial step for the
in.clear system to be stable and effective.
If water quality is not good after use, only the boost
level should be adjusted, not the maintenance level.
direct to function
selection wheel:
– on/off
– bromicharge
– boost level
– maintenance