8. Press key 'c' to read configuration. The values you programmed (test bit 1, config = 0x55) 
should be displayed as shown in the  screen below: 
9. When the test bit is set to '1', test data can be placed into the data buffer through the SPI 
bus, this is a test feature which tests a large portion of the device, but not the comparator 
and threshold setting circuits. Press key 'r' to read data, only the test data should now be 
read, as shown below: 
 
10. To configure all U1 sensors as GND/Open press key 'w' and set test bit to 0, then enter FF.  
Press 'c' to read registers back to the screen and verify that the configuration reads; 
 
All 8 sensors are now set to detect the GND/Open states. The short cut keys 'G' and 'S' can also 
be used the set all sensors to GND/Open and Supply/Open respectively. 
 
QSG‐8428‐R Rev. A 
 
 