Advertisement

Quick Links

MS ICE MAKER MAINTANEANCE

1. AIR CONDENSER CLEANING:

1.
Disconnect the unit from the electricity.
2.
Clean condenser using a vacuum cleaner, soft brush or low pressure air. Clean
from top to bottom, not side to side. Be careful not to bend the condenser fins.
3.
Connect the unit to the electricity.

2. WATER CIRCUIT CLEANING:

1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Disconnect the condenser water inlet and outlet .
4.
Prepare the cleaning product Calklin or a solution with 50% phosphoric acid
and distilled water. Do not use hydrochloric acid. We recommend using
the cleaning product Calklin. The mixture is more effective if the water is
between 95ºF and 104ºF. Flow the solution through the condenser for about
10 minutes using a recirculating pump.
5.
Empty the product from the condenser and connect the condenser water intlet
and outlet.
6.
Open the water faucet.
Connect the unit to the electricity.

3. WATER FILTER REPLACE

1.
Disconnect the unit from the electricity.
2.
Closet the inlet water faucet.
3.
Close de faucets before and after the filter.
4.
Remove the old cartridge and replace it with a new one.
5.
Open all the closed faucets.
6.
Connect the unit to the electricity.
4. WATER CIRCUIT CLEANING:
1.
Remove the top cover screws to remove the cover.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ITV ICE MAKERS MS Series

  • Page 1 MS ICE MAKER MAINTANEANCE 1. AIR CONDENSER CLEANING: Disconnect the unit from the electricity. Clean condenser using a vacuum cleaner, soft brush or low pressure air. Clean from top to bottom, not side to side. Be careful not to bend the condenser fins. Connect the unit to the electricity.
  • Page 2 MS ICE MAKER MAINTANEANCE Remove the front door. Front panel Set Ice-wash switch to the OFF position (position 0) after ice falls from the evaporator at the end of a harvest cycle, or set the ice-wash switch to the OFF position and allow the ice to melt off the evaporator.
  • Page 3 MS ICE MAKER MAINTANEANCE MS 500 / 1000 Thickness Shield sensor Water level sensor Water tray Ice-wash switch Thickness MS 700 sensor Curtain Water level sensor Ice-wash switch Water tray Allow the solution to circulate in the water system for 30-40 minutes and then set the ice-wash switch to the OFF position.
  • Page 4 MS ICE MAKER MAINTANEANCE Clean the metal surfaces of the thickness sensor, water level sensor, the adjustment screw, the shield and the water tray with the cleaner solution using a brush (not a wire brush) or cloth. Water level Adjustment sensor screw Thickness...
  • Page 5 MS ICE MAKER MAINTANEANCE tray is 0.8 gal for MS 500 and 1.6 gal for MS 1000 and 0.9 gal for MS 700). Allow the solution to circulate in the water system for 20 minutes and then set the ice-wash switch to the OFF position. To purge out the sanitizer solution and residue move the ice-wash switch to the WASH position (drain and refill) and allow the water to circulate for 5 minutes and then move the switch to the OFF position (drain).