Download Print this page

American Standard SELECTRONIC 6053.193 Installation Instructions Manual page 7

I.c. faucet

Advertisement

Fig. 3
Unit #1
Already installed
BLACK &
WHITE
POWER
CONNECTIONS
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All control box covers must be removed before beginning to make daisy-chain connections.
Disconnect the first unit's Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 6).
For subsequent Units, refer to instructions below...
1. Remove COVERS from all CONTROL BOXES (3).
2. Remove solid black plug grommet from left side of all
CONTROL BOXES (3), and replace with GRAY
GROMMET (5b). (Supplied with each Faucet).
3. Insert pervious unit's 10' EXTENSION (11a) through
gray GROMMET (5b) and connect to single terminal
of Y-ADAPTER (11).
4. Feed CABLES (2) through the top of CONTROL BOX (3).
Connect one CABLE (2) to the SOLENOID CABLE (7),
and the other to either of the two available terminals of
the Y-ADAPTER (11). Connect the current unit's 10'
EXTENSION (10a) to available terminal of the
Y-ADAPTER (11).
5. Feed the other end of the 10 ft.EXTENSION (10b)
through the two GRAY GROMMETS (6a and 6b) and
connect to the single terminal of the next unit's
Y-ADAPTER (11). Place Y-ADAPTER (11) into
CONTROL BOX (3).
6. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY.
7. Reinstall CONTROL BOX COVERS. Tighten cover
screws firmly.
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or
cutting, splicing or modifying any components will void the warranty.
© 2019 AS America Inc.
AC POWER
SUPPLY
OR
Unit #2
*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
Fig. 3a
3
10a
2
11a
5b
11
5
7
Unit #3
10 ft.
EXTENSION
CABLE
Unit #2 Detail
6a
2
7
M965651 Rev. 2.0 (3/19)
10b
6b

Advertisement

loading

This manual is also suitable for:

Selectronic 6055.193Selectronic 605b.193