Roughing-in Dimensions
(127mm)
(127mm)
5"
5"
(53mm)
(53mm)
2-1/8" DIA.
2-1/8" DIA.
32mm
32mm
(1-1/4) DIA.
(1-1/4) DIA.
413mm
413mm
(16-1/4)
(16-1/4)
81mm
81mm
(3-3/16)
(3-3/16)
3/8" COMP.
3/8" COMP.
RECOMMENDED TOOLS
1. Slip Joint Pliers
2. Adjustable Wrench
3. Plumbers' Putty or Caulking
4. Phillips Screwdriver
5. Flat Blade Screwdriver
6. Electric Drill & 1/4" Drill Bit
7. Tape Measure

FAUCET INSTALLATION

1
SPOUT ASSEMBLY INSTALLATION;
Fig. 1
Turn off hot and cold water
CAUTION
supplies before beginning.
1. Insert CABLES (1), FLEX HOSE (2) and SPOUT
SHANK (3) through center hole of mounting surface.
2. Assemble "C" WASHER (4) and LOCKNUT (5)
onto SPOUT SHANK (3) from underside of
mounting surface.
3. Align FAUCET and tighten LOCKNUT (5).
Note: 4" and 8" Deck Plates are available for other
installations, see page one for information.
© 2019 AS America Inc.
(243mm)
(243mm)
9-9/16"
9-9/16"
(133mm)
(133mm)
5-1/4"
5-1/4"
MOUNTING
MOUNTING
SURFACE
SURFACE
60mm
60mm
(2-3/8) MAX.
(2-3/8) MAX.
125mm
125mm
(4-7/8)
(4-7/8)
114mm
114mm
(4-1/2)
(4-1/2)
500mm
500mm
(20")
(20")
GENERAL DESCRIPTION
Electronic faucet with proximity operation. Vandal resistant,
solid brass construction, single post mounting. Operates on DC
(battery/power pack) or AC permanent power (plug-in/hardwire).
In-line strainer for solenoid is integral. Single inlet 3/8
compression, built-in check valves, and flexible stainless steel
16-1/4" reach inlet hose for spout connection.
Note: All plumbing and electrical wiring must be installed
in accordance with applicable codes, regulations
and standards.
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied cables,
or cutting, splicing or modifying any components will void
the warranty.
RECOMENDED ELECTRICAL BOX OR
RECOMENDED ELECTRICAL BOX OR
EQUIVALENT BY OTHERS
EQUIVALENT BY OTHERS
4" (102mm) SQ. X 3-1/2" (89mm) DEEP ELECTRICAL BOX
4" (102mm) SQ. X 3-1/2" (89mm) DEEP ELECTRICAL BOX
1524mm
1524mm
(60)
(60)
HARD-WIRED AND MULTI AC 10' MAX. CABLE LENGTH
HARD-WIRED AND MULTI AC 10' MAX. CABLE LENGTH
1
3
4
5
Fig. 1
3
2
1
3
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
2
7
6
10'
SENSOR
CABLES
1
3
5
4
M965651 Rev. 2.0 (3/19)