4.3 Function Encoder

LCD display will show various timers such as
cooling time, timer 1, timer 2...etc. After
pressing the function encoder for over 2 seconds,
turn the knob to choose the timer needed to be
changed. Press this knob to confirm the timer
needed altered and turn it again to alter the
value, and then press it again to confirm this
alteration.
T5: cooling time timer, Range 0-0.6S
T1: see A16 timer 1
T2: see A16 timer 2
T4: Press bar delay time, Range 0-3S
PH1> 0: Photo eye no function (Disable)
1: Photo eye has function (Enable)
PH1-N> 0: only one strap cycle when PH1 is
activities.
1: continuous strap cycles when
PH1 is activated and cycle will
stop until the package leaves.
SQ6> 0: sensor for chute home position no
function (Disable)
1: sensor for chute home position has
function (Enable)
Press>0: Press device no function (Disable)
(for TP-702P only)
1: Press device has function (Enable)
(for TP-702P only)
Ready
<-
<-
<-
<-
<-
<-
Ready
-A22-
Press encoder
over 2S
Timer
TEC
Select Timer and
press encoder
Turn encoder right
T5:
0 - 60
000
Turn encoder right,
select the timer
needs to be altered
and press encoder
T5:
0 - 60
000
Turn encoder to
change the value
Then press encoder
T5 :
0 - 60
010
Turn encoder left
to <- and press
encoder to exit setting
Timer
TEC
Turn encoder left to
<- and press encoder
to exit setting
Finish setting