If it is necessary to make adjustments inside the machine during operation, after a strap
jam for example, the rear table top can be unscrewed. Observe caution as the machine is
still fully functional with the covers removed. When the front table top is opened, safety
switch B6-1 is activated. This will remove power but the heating element will keeping
heating.
CAUTION!
The heating unit operates at a very high temperature in order to melt the PP
strapping. To prevent burns, avoid contact with this area.

2.6 Technical Specification

2.6.1 Electrical Specification
System configuration:
Nominal power:
Rated current:
Rated voltage:
Rated frequency:
Type of current
1L+N+PE (Ground)
0.5kW
3A
220V/230V/240V
50Hz
AC - single phase
-A9-
1L+N+PE (Ground)
0.5kW
5A
110V
60Hz
AC - single phase