L-Acoustics A15i Series Owner's Manual page 71

Table of Contents

Advertisement

2. Remove the placeholder screws and connect the enclosures at the top using the rigging plates.
End links
Start by using end rigging plates on the leftmost or rightmost enclosure of the array, then proceed towards the
other side.
Do not add inter-element angle with A15iFOCUS-LINK in radial congurations.
Do not tighten the screws until all rigging plates are secured.
3. Tighten all the screws on the rigging plates.
Apply a torque of 5 N.m.
4. Secure the A15i-LIFT bars on the array.
a) Disconnect the rigging axis at the rear of A15i-LIFT.
A15i owner's manual (EN) version 1.0
Rigging procedures
end rigging plates
71

Hide quick links: