Model 8200
Adjust the key position of the touch screen after replacing the touch panel, or if the key
position is out of alignment.
B
Main
Slave
DC1
Brightness
Foot UD
Read Card
PH Sensor
Solenoid
TTP Adjust
Self Check
Clear Set
PRESS
MARK
4
1

Touch Screen Calibration

C
Sensor Off
Aging
D
ADJUSTMENT END
2
3
5
Note: Do not press any key other than those described in
A
the following sections. These keys are not for servicing
but for factory use only.
1. Turn the Power switch
Stop button
LCD screen shows the adjusting mode.
A
Power switch
B
Start/Stop button
2. The LCD screen will show the Adjusting mode
C
Adjusting mode
3. Press the Start/Stop button again.
Caution: Do not press any keys in this mode.
4. The LCD screen will show the Special adjusting
D
mode
D
Special adjusting mode
5. Press the "TTP Adjust" key.
Caution: Do not press the "Self Check" or "Clear Set"
key, which are only for the factory use.
6. Press the cross with the tip of the extra spool pin, from
steps 1 to 5 in this order.
7. Having pressed the last (5th) key, the LCD screen
shows "ADJUSTMENT END" and "OK".
8. Turn the power switch off.
9. Turn the power switch on again to check the adjustment
result.
OK
22
A
on while pressing the Start/
. Do not release the button until the
B
.
Caution:
Pressing the "Clear Set"
key will erase all the program
settings.
Note: Do not press the "Self Check"
key which is not for servicing but for
factory use only.
.
C