Installation - ZANKER KBA23022SK User Manual

Table of Contents

Advertisement

Available languages

Available languages

or an electrician to change the electrical
components.
The mains cable must stay below the level of the
mains plug.
Connect the mains plug to the mains socket only at
the end of the installation. Make sure that there is
access to the mains plug after the installation.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
Use
Warning! Risk of injury, burns, electric
shock or fire.
The appliance contains flammable gas,
isobutane (R600a), a natural gas with a high level of
environmental compatibility. Be careful not to cause
damage to the refrigerant circuit containing isobutane.
Do not change the specification of this appliance.
Do not put electrical appliances (e.g. ice cream
makers) in the appliance unless they are stated
applicable by the manufacturer.
If damage occurs to the refrigerant circuit, make
sure that there are no flames and sources of ignition
in the room. Ventilate the room.
Do not let hot items to touch the plastic parts of the
appliance.
Do not store flammable gas and liquid in the
appliance.
Do not put flammable products or items that are wet
with flammable products in, near or on the
appliance.
Do not touch the compressor or the condenser.
They are hot.
Internal lighting
Warning! Risk of electric shock.

Installation

Warning! Refer to Safety chapters.
Location
Refer to the assembly instructions for the
installation.
To ensure best performance, install the appliance well
away from sources of heat such as radiators, boilers,
14
The type of lamp used for this appliance is for
household appliances only. Do not use it for house
lighting.
Care and cleaning
Warning! Risk of injury or damage to the
appliance.
Before maintenance, deactivate the appliance and
disconnect the mains plug from the mains socket.
This appliance contains hydrocarbons in the cooling
unit. Only a qualified person must do the
maintenance and the recharging of the unit.
Regularly examine the drain of the appliance and if
necessary, clean it. If the drain is blocked, defrosted
water collects in the bottom of the appliance.
Service
To repair the appliance contact the Authorised
Service Centre.
Use original spare parts only.
Disposal
Warning! Risk of injury or suffocation.
Disconnect the appliance from the mains supply.
Cut off the mains cable and discard it.
Remove the door to prevent children and pets to be
closed inside of the appliance.
The refrigerant circuit and the insulation materials of
this appliance are ozone-friendly.
The insulation foam contains flammable gas.
Contact your municipal authority for information on
how to discard the appliance correctly.
Do not cause damage to the part of the cooling unit
that is near the heat exchanger.
direct sunlight etc. Make sure that air can circulate
freely around the back of the cabinet.
Positioning
Install the appliance in a dry, well ventilated indoors
where the ambient temperature corresponds to the
climate class indicated on the rating plate of the
appliance.