INSTALLATION | GUARANTEE | ENVIRONMENT AND RECYCLING

Specification

9.1.3 Cleaning the pressure reducing valve
f Rotate the shut-off valve 90° upwards to close the cold water
f
supply.
f Open the tap to depressurise the water heater.
f
f Rotate the setting screw in the threaded cap fully anti-clock-
f
wise to release the spring tension.
f Remove the cap.
f
f Remove the pressure reducing valve from the casing.
f
f Clean the pressure reducing valve with tap water.
f
f Refit the pressure reducing valve and refit the cap.
f
f Return the system to its original pressure (see chapter „Com-
f
missioning/Setting the pressure reducing valve").
f If this does not resolve the problem, replace the pressure
f
reducing valve.
9.1.4 Testing the non-return valve
f Check the non-return valve annually.
f
f Shut off the water and remove the cap from the test
f
connection.
No water must be expelled.
f Replace the non-return valve if it leaks.
f
10. Specification

10.1 Dimensions

Ø10
Ø 10 x 450
www.stiebel-eltron.com
Ø 10
Ø 14 x 230
100-200

10.2 Data table

Max. permissible pressure
Max. inlet pressure
Safety valve response pressure
Pressure reducing valve
Drip water connection
Type of installation
Connection
Guarantee
The guarantee conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.
SVMT
073499
MPa
1
MPa
0.56
MPa
0.7
X
X
Finished walls
G 1/2 A
SVMT |
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

073499

Table of Contents