Emerson PENBERTHY H Series Installation, Operation And Maintenance Instructions

Flat glass gages

Advertisement

Quick Links

PENBERTHY SERIES H FLAT GLASS GAGES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be read fully and understood

TABLE OF CONTENTS

Product warranty ................................................ 1
1. About the manual .......................................... 2
2. Introduction ................................................... 2
2.1 System description ................................. 2
3. Available models ........................................... 2
4. Inspection ...................................................... 4
4.1 Glass inspection ..................................... 4
4.2 User rating inspection............................ 4
5. Installation ..................................................... 4
5.1 Piping strain ............................................ 4
5.3 Mirror viewing ......................................... 4
5.4 Nut retorquing ........................................ 5
5.5 Belleville washers .................................. 5
6. Operation ....................................................... 5
6.1 Hydrostatic test ...................................... 6
7. Maintenance .................................................. 6
7.1 Maintenance procedures ....................... 6
7.2 Troubleshooting ..................................... 7
8.1 Disassembly ........................................... 7
8.3 Reassembly ............................................ 8
9. Disposal at end of useful life ........................ 9
10. Telephone assistance ................................... 9
11. Exploded parts diagrams ............................ 10
valves.emerson.com
Tables and figures
Table 1 Design ratings of RH and RHR gage .. 3
Table 2 Design ratings of TH and THR gage ... 3
Table 3 Design ratings of TH and
THR gage - 316 STS covers................. 3
Table 4 Bolt torque values ............................... 5
Figure 1 Nut tightening sequence ..................... 5
Figure 2 Belleville washer position ................... 5
Figure 3 Gage disassembly ................................ 7
Figure 4 Nut loosening sequence ..................... 7
Figure 5 Exploded parts diagram of
transparent gage ............................... 10
Figure 6 Exploded parts diagram of
reflex gage ......................................... 10

Product warranty

Emerson warrants its Penberthy products
as designed and manufactured to be free
of defects in the material and workmanship
for a period of one year after the date of
installation or eighteen months after the date
of manufacture, whichever is earliest. Emerson
will, at its option, replace or repair any products
which fail during the warranty period due to
defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to Emerson and obtain written
authorization to return the product. Thereafter,
the product shall be returned to Emerson with
freight paid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired or
otherwise altered outside of Emerson's factory
or if it has been subject to misuse, neglect or
accident.
The responsibility of Emerson hereunder is
limited to repairing or replacing the product
at its expense. Emerson shall not be liable
for loss, damage or expenses related directly
or indirectly to the installation or use of
its products, or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
buildings, personnel or property, by reason of
the installation or use of its products.
© 2017 Emerson. All rights reserved.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless made in
writing and signed by the company's general
manager or director of engineering.
VCIOM-04073-EN 17/05

Advertisement

Table of Contents
loading

Summary of Contents for Emerson PENBERTHY H Series

  • Page 1: Table Of Contents

    Before installation these instructions must be read fully and understood Tables and figures This is Emerson’s sole warranty and in lieu of Table 1 Design ratings of RH and RHR gage .. 3 all other warranties, expressed or implied which Table 2 Design ratings of TH and THR gage ...
  • Page 2: About The Manual

    SAFETY INSTRUCTIONS compatibility with the media in the gage. Glass: allows for visual observation of the Emerson does not have any control over the manner in which its gage is handled, installed or process fluid in the chamber. Cushion: acts as a protective buffer between...
  • Page 3: Design Ratings At Maximum And Minimum Operating Temperatures

    PENBERTHY SERIES H FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 3.1 Design ratings at maximum and minimum operating temperatures TABLE 1 Gasket Glass Model RH and RHR reflex material size Wetted parts material steel or stainless steel w/B7 bolting Grafoil (standard) or non-asbestos 4000 psig (27580 kPa) at -20°F (-29°C) to 100°F (38°C)
  • Page 4: Inspection

    PENBERTHY SERIES H FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 4 INSPECTION 5 INSTALLATION On receipt of a liquid level gage, check all Installation should only be undertaken by components carefully for damage incurred in qualified, experienced personnel who are shipping.
  • Page 5: Nut Retorquing

    PENBERTHY SERIES H FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 5.4 Nut retorquing 5.5 Belleville washers FIGURE 1 Nut re-torque is vital to the operation of a liquid Belleville washers are used to reduce the need Nut tightening sequence level gage because gaskets take permanent to retorque nuts.
  • Page 6: Hydrostatic Test

    Concentration of chemicals can accelerate the corrosion rate. DO NOT proceed with operation of a liquid level gage until gaskets have been replaced by Emerson cannot create a blanket maintenance schedule for every application. following Section 8 disassembly-reassembly instructions.
  • Page 7: Troubleshooting

    PENBERTHY SERIES H FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 7.2 Troubleshooting 1. Lay transparent style gage on cut pieces of FIGURE 3 Problem: Glass becomes etched or clouded wood as shown in Figure 3, to keep it from Block of wood prematurely in service.
  • Page 8: Inspection Of Glass Seating Surfaces

    PENBERTHY SERIES H FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 8.2 Inspection of glass seating surfaces 3. For reflex style and belleville reflex style gages, lay out covers on cut 1 x 4 pieces of Clean the glass seating surfaces on the liquid chamber and cover with a soft metal scraper wood along bench, side by side, with liquid chamber.
  • Page 9: Disposal At End Of Useful Life

    Stringent obtain a Return Authorization (R.A.) number inspection of the seating surface and chamber from Emerson before returning anything. tolerances should be exercised. Extreme care Failure to do so will result in the unit being...
  • Page 10: Exploded Parts Diagrams

    PENBERTHY SERIES H FLAT GLASS GAGES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 11 EXPLODED PARTS DIAGRAMS FIGURE 5 FIGURE 6 PARTS LIST Transparent Reflex Item Description Cover Chamber Glass Gasket Cushion Shield Bolt/U-bolt Washer Nameplate Band RECOMMENDED SPARE PARTS Item Description Qty.

This manual is also suitable for:

Penberthy rhPenberthy rhrPenberthy thPenberthy thr

Table of Contents